How do you quickly and reliably confirm the correct depth of an endotracheal tube (ETT) when advanced equipment isn’t available? While capnography, radiography, and bronchoscopy are reference standards, anaesthesiologists often rely on simpler bedside techniques in daily practice. A new study in the Indian Journal of Anaesthesia puts suprasternal tactile cuff ballotability to the test—could this hands-on method improve airway safety?

Background: The Challenge of ETT Depth Verification

Auscultation and chest expansion alone miss up to 55% of endobronchial intubations. Radiography, while accurate, is costly and slow; bronchoscopy and ultrasound require equipment and expertise. Tactile cuff ballotability—feeling for ETT cuff movement above the suprasternal notch when compressing the pilot balloon—offers a low-tech, rapid alternative.

Study Design: Ballotability vs. Radiographic Standard

This prospective diagnostic accuracy study enrolled 72 non-obese adults receiving general anaesthesia for neuroradiological procedures. After intubation, three trained anaesthesiologists independently assessed whether cuff ballotability could be felt above the suprasternal notch. The gold standard was fluoroscopic confirmation of the ETT cuff at or above the lower border of the T2 vertebra, an accepted marker for safe tube depth. Interobserver agreement and tip-to-carina distances were also analyzed.

Key Results: High Sensitivity, Moderate Specificity, Excellent Agreement

Sensitivity: 98.1%—cuff ballotability correctly identified nearly all ETTs at the proper depth.

Specificity: 60%—some false positives occurred, but the test was rarely falsely negative.

Positive Predictive Value (PPV): 86.4%; Negative Predictive Value (NPV): 92.3%.

Interobserver Agreement: Fleiss’ kappa 0.77, indicating excellent consistency among clinicians.

Clinical Insight: If ballotability is not felt, the odds of incorrect tube depth are high—making this a strong screening tool.

Implications: Practical Bedside Application

While not a replacement for imaging or capnography, suprasternal ballotability is reproducible and requires no extra devices or time. It performs especially well as a screening test to rule out malpositioned ETTs in routine adult cases. Its moderate specificity means it should be complemented by other methods in high-risk or complex settings.

Conclusion

Tactile cuff ballotability above the suprasternal notch is a simple, sensitive, and reliable bedside test for confirming correct ETT depth in non-obese adults. With excellent agreement among observers, this technique can enhance airway safety—especially when advanced imaging is not an option.

KEY points

Suprasternal cuff ballotability is highly sensitive for detecting correct ETT depth.

Negative ballotability strongly suggests malposition and warrants immediate review.

The method shows excellent reproducibility among trained anaesthesiologists.

Specificity is moderate; combine with other assessments for complex cases.

This low-tech, rapid test is a practical addition to routine airway management.

Citation:

Selvam V, Ganesh V, Vyas S, Yaddanapudi LN, Bhagat H. Positive predictive value of tactile tracheal tube cuff ballotability above the suprasternal notch in detecting the correct positioning of the tracheal tube – A diagnostic accuracy study. Indian Journal of Anaesthesia. 2026;70(9):1034-41. DOI: 10.4103/ija.ija_1678_25

Tags:    

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .