Use of fine cotton swabs may reduce bleeding without compromising disinfection during Nasotracheal Intubation: Study
Nasotracheal intubation (NTI) is essential for surgeries that demand unobstructed access to the surgical area and for patients with respiratory complications. Recent study by Hirohata et al. aimed to investigate the efficacy of pre-nasotracheal intubation nasal disinfection using different cotton swab sizes. The researchers hypothesized that smaller swabs could potentially reduce bleeding while maintaining disinfection effectiveness. The randomized controlled trial involved patients scheduled for general anesthesia with nasotracheal intubation (NTI) who were divided into two groups: one using large cotton swabs (LCS) and the other using fine cotton swabs (FCS). The study collected samples to assess bacterial counts before disinfection (sample A), after disinfection with LCS or FCS (sample B), and from the endotracheal tube post-surgery (sample C). Results indicated that there was no significant difference in bacterial reduction between LCS and FCS groups after disinfection with benzalkonium chloride (BZK). However, a notable finding was that nasal bleeding occurred more frequently in the LCS group compared to the FCS group.
Patient Characteristics and Outcomes
The study involved 129 patients aged 20-70, ASA-PS class 1 or 2, with random assignment to LCS or FCS groups. The analysis revealed no significant difference in disinfection efficacy between the two swab sizes but highlighted a clear disparity in nasal bleeding incidence. Subsequent comparisons of bacterial count changes between samples A and B, and samples A and C, showed similar outcomes for both LCS and FCS groups.
Conclusions and Recommendations
The conclusion of the study recommended the use of FCS for nasal disinfection before NTI in ASA 1–2 patients due to the reduced risk of bleeding without compromising disinfection. The results emphasized that cotton swab thickness did not impact disinfection efficacy, with FCS being preferred over LCS to minimize nasal bleeding risk. The study's findings contribute to optimizing NTI procedures and enhancing patient safety during anesthesia. The research underscored the importance of selecting appropriate disinfection methods to minimize complications associated with NTI, such as nasal bleeding and potential bacteremia.
Key Points
1. The study by Hirohata et al. focused on investigating the effectiveness of pre-nasotracheal intubation nasal disinfection using different cotton swab sizes. The researchers hypothesized that using smaller swabs could potentially reduce bleeding while maintaining disinfection efficacy.
2. The randomized controlled trial included 129 patients scheduled for general anesthesia with nasotracheal intubation, divided into two groups: one using large cotton swabs (LCS) and the other using fine cotton swabs (FCS). Samples were collected to assess bacterial counts before disinfection, after disinfection with either LCS or FCS, and from the endotracheal tube post-surgery.
3. Results indicated that there was no significant difference in bacterial reduction between the LCS and FCS groups after disinfection with benzalkonium chloride (BZK). However, a noteworthy finding was that nasal bleeding occurred more frequently in the LCS group compared to the FCS group.
4. Patient characteristics included individuals aged 20-70, ASA-PS class 1 or 2, randomly assigned to either LCS or FCS groups. The analysis showed no significant difference in disinfection efficacy between the two swab sizes but highlighted a clear difference in nasal bleeding incidence
5. Comparisons of bacterial count changes between samples A and B, and samples A and C, demonstrated similar outcomes for both LCS and FCS groups, reinforcing the findings of comparable disinfection effectiveness regardless of swab size.
6. The study concluded by recommending the use of FCS for nasal disinfection before nasotracheal intubation in ASA 1–2 patients due to the reduced risk of bleeding without compromising disinfection efficacy. The research serves to optimize nasotracheal intubation procedures, enhance patient safety during anesthesia, and stress the importance of selecting appropriate disinfection methods to minimize complications like nasal bleeding and potential bacteremia.
Reference –
Makoto Hirohata et al. (2024). Microbiological Comparison Of The Disinfecting Efficacy Of Small And Large Cotton Swabs In Nasotracheal Intubation: A Randomized Trial. *BMC Anesthesiology*, 24. https://doi.org/10.1186/s12871-024-02804-2
Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.