Anterior-lateral positioning of electrodes better for biphasic cardioversion of AF

Written By :  Dr. Shravani Dali
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2022-03-15 04:00 GMT   |   Update On 2022-03-15 04:01 GMT
Advertisement

According to a recent study published in Circulation, Anterior-lateral positioning is superior to anterior-posterior electrode positioning in biphasic cardioversion of atrial fibrillation.

Smaller randomized studies have reported conflicting results regarding the optimal electrode position for cardioverting atrial fibrillation. However, anterior-posterior electrode positioning is widely used as a standard and believed to be superior to anterior-lateral electrode positioning. Therefore, we aimed to compare anterior-lateral and anterior-posterior electrode positioning for cardioverting atrial fibrillation in a multicenter randomized trial.

Advertisement

In this multicenter, investigator-initiated, open-label trial, we randomly assigned patients with atrial fibrillation scheduled for elective cardioversion to either anterior-lateral or anterior-posterior electrode positioning. The primary outcome was the proportion of patients in sinus rhythm after the first shock. The secondary outcome was the proportion of patients in sinus rhythm after up to 4 shocks escalating to maximum energy. Safety outcomes were any cases of arrhythmia during or after cardioversion, skin redness, and patient-reported periprocedural pain.

Results:

Researchers randomized 468 patients. The primary outcome occurred in 126 patients (54%) assigned to the anterior-lateral electrodeposition and in 77 patients (33%) assigned to the anterior-posterior electrodeposition (risk difference, 22 percentage points [95% CI, 13-30]; P<0.001). The number of patients in sinus rhythm after the final cardioversion shock was 216 (93%) assigned to anterior-lateral electrode positioning and 200 (85%) assigned to anterior-posterior electrode positioning (risk difference, 7 percentage points [95% CI, 2-12]). There were no significant differences between groups in any safety outcomes.

Thus, anterior-lateral electrode positioning was more effective than anterior-posterior electrode positioning for biphasic cardioversion of atrial fibrillation. There were no significant differences in any safety outcome.

Reference:

Anterior-Lateral Versus Anterior-Posterior Electrode Position for Cardioverting Atrial Fibrillation by Anders Sjørslev Schmidt et al. published in the Circulation.

Keywords:

atrial fibrillation, electric countershock, electrodes, Anterior-lateral positioning, an anterior-posterior electrode for biphasic cardioversion, electrode positioning for atrial fibrillation, biphasic cardioversion of atrial fibrillation, Circulation, Anders Sjørslev Schmidt, Kasper Glerup Lauridsen, Dorthe Svenstrup Møller, Per Dahl Christensen, Karen Kaae Dodt, Hans Rickers, Bo Løfgren, Andi Eie Albertsen


Tags:    
Article Source : Circulation

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News