Cerebral protection system reduces stroke risk in patients undergoing TAVR: JACC

Written By :  Medha Baranwal
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2020-10-11 15:45 GMT   |   Update On 2020-10-12 08:33 GMT
Advertisement

USA: The use of the Sentinel cerebral protection system (CPS) in patients undergoing TAVR lowers the risk of in-hospital mortality and ischemic stroke, suggests a recent study in the journal JACC: Cardiovascular Interventions. Further, the use of CPS did not increase the risk of procedural complications but increased the cost of the index hospitalization.

Sentinel CPS is the only device approved by the US FDA for cerebral embolic protection. However, the role in the prevention of clinical ischemic stroke has been controversial. To have some clarity on the same, Michael Megaly, Abbott Northwestern Hospital, Minneapolis, Minnesota, and colleagues evaluated in-hospital outcomes with the use of the Sentinel cerebral protection system in patients undergoing transcatheter aortic valve replacement (TAVR).

Advertisement

The researchers queried the Nationwide Inpatient Sample database from the last three quarters of 2017 after the approval of the Sentinel CPS device, for identifying the TAVR hospitalizations. 

The Nationwide Inpatient Sample database from the last three quarters of 2017, after the approval of the Sentinel CPS device, was queried to identify hospitalizations for TAVR. A 1:2 propensity score-matched analysis to compare in-hospital outcomes with versus without the use of the CPS. A total of 36,220 weighted discharges of patients who underwent TAVR (525 with the CPS and 35,695 without) were identified.

The primary outcome was the occurrence of ischemic strokes. 

Key findings of the study include:

  • The overall percentages of ischemic and hemorrhagic strokes were 2.4% and 0.2%, respectively.
  • After propensity score matching (525 CPS, 1,050 no CPS), the risk for ischemic stroke was lower with use of the CPS (1 % vs. 3.8%,).
  • The cost of the index hospitalization was higher with use of the CPS ($47,783 vs. $44,578).
  • In multivariate regression analysis, use of the CPS was independently associated with a lower risk for ischemic stroke.

"Use of the Sentinel CPS in patients undergoing TAVR is associated with a lower incidence of ischemic stroke and in-hospital mortality, without an increased risk for procedural complications but with an increased cost of the index hospitalization," concluded the authors.

The study, "Ischemic Stroke With Cerebral Protection System During Transcatheter Aortic Valve Replacement," is published in the journal JACC: Cardiovascular Interventions.

DOI: https://interventions.onlinejacc.org/content/13/18/2149

Tags:    
Article Source : JACC: Cardiovascular Interventions

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News