Automated method for monitoring tooth wear progression faster and accurate for full-arch intraoral scanning : Study

Written By :  Dr. Shravani Dali
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2024-09-22 15:15 GMT   |   Update On 2024-09-23 06:07 GMT
Advertisement

An automated method for monitoring tooth wear progression faster and more accurately for full-arch intraoral scanning suggests a study published in the Journal of Dentistry.

This study aimed to develop and evaluate a fully automated method for visualizing and measuring tooth wear progression using pairs of intraoral scans (IOSs) in comparison with a manual protocol. Eight patients with severe tooth wear progression were retrospectively included, with IOSs taken at baseline and 1-year, 3-year, and 5-year follow-ups. For alignment, the automated method segmented the arch into separate teeth in the IOSs.

Advertisement

Tooth pair registration selected tooth surfaces that were likely unaffected by tooth wear and performed point set registration on the selected surfaces. Maximum tooth profile losses from baseline to each follow-up were determined based on signed distances using the manual 3D Wear Analysis (3DWA) protocol and the automated method. The automated method was evaluated against the 3DWA protocol by comparing tooth segmentations with the Dice-Sørensen coefficient (DSC) and intersection over union (IoU). The tooth profile loss measurements were compared with regression and Bland-Altman plots. Additionally, the relationship between the time interval and the measurement differences between the two methods was shown.

Results: The automated method completed within two minutes. It was very effective for tooth instance segmentation (826 teeth, DSC = 0.947, IoU = 0.907), and a correlation of 0.932 was observed for agreement on tooth profile loss measurements (516 tooth pairs, mean difference = 0.021mm, 95% confidence interval = [-0.085, 0.138]). The variability in measurement differences increased for larger time intervals. The proposed automated method for monitoring tooth wear progression was faster and not clinically significantly different in accuracy compared to a manual protocol for full-arch IOSs. General practitioners and patients can benefit from the visualization of tooth wear, allowing quantifiable and standardized decisions concerning therapy requirements of worn teeth. The proposed method for tooth wear monitoring decreased the time required to less than two minutes compared with the manual approach, which took at least two hours.

Reference:

Niels van Nistelrooij, Eva Maier, Hilde Bronkhorst, Luuk Crins, Tong Xi, Bas A.C. Loomans, Shankeeth Vinayahalingam. Automated monitoring of tooth wear progression using AI on intraoral scans, Journal of Dentistry, Volume 150, 2024, 105323, ISSN 0300-5712, https://doi.org/10.1016/j.jdent.2024.105323.

Tags:    
Article Source : Journal of Dentistry

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News