Flapless placement of zygomatic implant guided by dynamic navigation safe and accurate

Written By :  Dr. Shravani Dali
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2023-03-03 14:30 GMT   |   Update On 2023-03-04 06:36 GMT

Flapless placement of zygomatic implant guided by dynamic navigation safe and accurately suggests a new study published in the Journal of DentistryThe assessment of the accuracy of flapless placement of zygomatic implants in edentulous maxilla using dynamic navigation.A randomized controlled trial was carried out on 20 patients. Patients were randomized into two groups, the flapless (Group...

Login or Register to read the full article

Flapless placement of zygomatic implant guided by dynamic navigation safe and accurately suggests a new study published in the Journal of Dentistry

The assessment of the accuracy of flapless placement of zygomatic implants in edentulous maxilla using dynamic navigation.

A randomized controlled trial was carried out on 20 patients. Patients were randomized into two groups, the flapless (Group 1; n=10) and the conventional (Group 2; n=10). In each case two zygomatic implants were inserted under local anaesthesia, one on the right and one on the left side guided by a dynamic navigation system. The surgical procedure was identical in the two groups except for the reflection of the mucoperiosteal flap which was eliminated in the flapless cases. Postoperative CBCT scans were used to assess the accuracy of the placement of zygomatic implants.

Results

Osseointegration was achieved for all the implants, except one case in the flapless group. Statistically significant differences in the accuracy of the position of the zygomatic implants was found between the flapless and the conventional groups, measured at the apex and the entry points of the implants (p < 0.01).

The average apical and coronal deviations were 5 mm and 3 mm, respectively; the angular deviation was 6°, and 2 mm vertical apical disparity was detected between the planned and the achieved surgical position.

Perforation of the Schneiderian membrane was noted in three cases, one in flapless group and two in the conventional group.

Flapless placement of zygomatic implants guided by dynamic navigation offered satisfactory safety and accuracy. This is the first clinical trial to prove the feasibility and accuracy of flapless placement of zygomatic implant with minimal morbidity. The study highlights the innovative reflection of the Schneiderian membrane under guided surgical navigation. The procedure can be performed under local anaesthesia, which offers clinical advantages. Adequate training on the use of dynamic navigation is mandatory before its use in clinical cases.

Reference:

Ashwini Bhalerao, Madhulaxmi Marimuthu, Abdul Wahab, Ashraf Ayoub,

Dynamic navigation for zygomatic implant placement: A randomized clinical study comparing the flapless versus the conventional approach, Journal of Dentistry, Volume 130, 2023,

104436, ISSN 0300-5712, https://doi.org/10.1016/j.jdent.2023.104436.

Keywords:

Flapless, placement, zygomatic, implant, guided, dynamic, navigation, safe, accurate, Journal of Dentistry, Ashwini Bhalerao, Madhulaxmi Marimuthu, Abdul Wahab, Ashraf Ayoub

Tags:    
Article Source : Journal of Dentistry

Disclaimer: This site is primarily intended for healthcare professionals. Any content/information on this website does not replace the advice of medical and/or health professionals and should not be construed as medical/diagnostic advice/endorsement/treatment or prescription. Use of this site is subject to our terms of use, privacy policy, advertisement policy. © 2024 Minerva Medical Treatment Pvt Ltd