Irradiance using LED-Light curing units in dentistry may damage pulp

Written By :  Dr. Shravani Dali
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2022-06-11 01:00 GMT   |   Update On 2022-06-11 09:49 GMT
Advertisement

Researchers have found in a new study that irradiance using light-emitting diode (LED)-light-curing units (LCUs) is associated with pulp damage in dentistry. Therefore clinicians should be aware of LED-LCU settings and possible high temperatures generated according to a recent study published in the Clinical Oral Investigations

To investigate how heat development in the pulp chamber and coronal surface of natural teeth with and without cusps subjected to irradiance using light-emitting diode (LED)–light-curing units (LCUs) is associated with (i) irradiance, (ii) time, (iii) distance, and (iv) radiant exposure.

Advertisement

Three different LED-LCUs were used. Their irradiance was measured with a calibrated spectrometer (BlueLight Analytics Inc., Halifax, Canada). An experimental rig was constructed to control the thermal environment of the teeth. The LED-LCU tip position was accurately controlled by a gantry system. Tooth surface temperature was measured by thermography (ThermaCAM S65 HS, FLIR Systems, Wilsonville, USA) and pulp chamber temperature with a thermocouple. LED-LCU tip distance and irradiation times tested were 0, 2, and 4 mm and 10, 20, and 30 s, respectively. Ethical permission was not required for the use of extracted teeth.

Results

  • Maximum surface and pulp chamber temperatures were recorded in teeth without cusps (58.1 °C ± 0.9 °C and 43.1 °C ± 0.9 °C, respectively).
  • Radiant exposure explained the largest amount of variance in temperature, being more affected by time than irradiance.

Thus, at all combinations of variables tested, repeated measurements produced consistent results indicating the reliability of the method used. Increased exposure time seems to be the factor most likely to cause tissue damage. The risk of superficial tissue damage at irradiances >1200 mW/cm2 is evident. There is a risk of pulp damage when only thin dentin is left at higher irradiances (>1200 mW/cm2). Clinicians should be aware of LED-LCU settings and possible high temperature generated.

Reference:

Light-curing units used in dentistry: factors associated with heat development—potential risk for patients by Mathieu Mouhat, et al. published in the Clinical Oral Investigations

https://link.springer.com/article/10.1007/s00784-016-1962-5



Tags:    
Article Source : Clinical Oral Investigations

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News