New technique most precise in the fabrication of complete denture metal bases: Study

Written By :  Dr. Shravani Dali
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2021-11-19 03:30 GMT   |   Update On 2021-11-19 03:30 GMT
Advertisement

The stereolithography apparatus (SLA) technique is the most precise and best method for denture base fabrication, as per a recent study published in the Journal of Prosthetic Dentistry.

Conventional fabrication of complete denture metal bases is being replaced by the computer-aided design and computer-aided manufacturing (CAD-CAM) systems. However, a comparative analysis of subtractive and additive CAD-CAM manufacturing techniques is lacking.

Advertisement

The purpose of this in vitro study was to compare the adaptation of complete denture metal bases fabricated by milling (subtractive manufacturing) and stereolithography apparatus (SLA) and digital light processing (DLP) (additive manufacturing).

Thirty metal bases were manufactured by using the milling (MIL group), SLA (SLA group), and DLP (DLP group) techniques. The silicone replica technique was used to evaluate the adaptation of the complete denture metal bases, and 30 silicone blocks were fabricated. The silicone block was cut equally in the canine, first molar, and second molar areas. The gap between the model and the metal base was measured by using a digital microscope at the 3 locations, and the measured data were statistically analyzed by using a statistical software program (α=.05).

The Results of the study are as follows:

The gaps measured at the 3 areas showed significant differences in all 3 groups (P<.05). At the anterior, middle, and posterior areas, the SLA group showed the narrowest gap (302 ±31 μm, 241 ±39 μm, 201 ±43 μm, respectively). The SLA group also had the narrowest total gap of the metal bases (218 ±33 μm).

Thus, the researchers concluded that the adaptation of the fabricated metal bases varied significantly across the techniques used but fell within a clinically allowable range. The SLA group was the most precise in the fabrication of complete denture metal bases. Further studies are required to analyze the effects of the layer thickness setting, wax elimination, and casting temperature on the adaptation of metal bases manufactured by using SLA.

Reference:

Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study by Seung-GyuYou et al. published in The Journal of Prosthetic Dentistry.

https://doi.org/10.1016/j.prosdent.2020.01.039



Tags:    
Article Source : The Journal of Prosthetic Dentistry

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News