Self-glazed zirconia Abutments Show Superior Fit Over Conventional Zirconia Abutments, finds study

Published On 2025-08-01 15:00 GMT   |   Update On 2025-08-01 15:00 GMT
Advertisement

Researchers have found in a new study that Self-glazed zirconia abutments exhibit better adaptation than conventional milled zirconia abutments at both the Ti base-abutment and implant-abutment interfaces. Additionally, the fit of one-piece Self-glazed zirconia abutments is comparable to that of prefabricated Ti-base abutments, indicating their clinical viability.

Self-glazed zirconia (SGZ), produced using a novel additive 3D gel deposition technology, has recently been employed to fabricate zirconia abutments. This in vitro study aimed to evaluate the adaptation of one-piece and two-piece all-ceramic SGZ implant abutments in comparison to conventional milled zirconia abutments. One-piece zirconia abutments and two-piece Ti-base zirconia abutments, sharing an identical 3D design, were fabricated using self-glazed zirconia via 3D gel deposition and conventional zirconia via milling, forming four groups: SGZ-A, SGZ-Ti, Lava-A, and Lava-Ti. Marginal gaps between the zirconia abutments and Ti-base were evaluated using micro-CT data, while gaps between the abutments and implant analogs were assessed on specimen cross-sections by using a stereomicroscope. Statistical analyses were conducted using the non-parametric Mann-Whitney U and Kruskal-Wallis tests with α set at 0.05. Results: For the two-piece zirconia abutments, the SGZ-Ti group(external gaps:31 ± 20 μm, internal gaps:4 ± 7 μm) exhibited significantly smaller marginal gaps between the zirconia abutment and the Ti-base compared to the Lava-Ti group(external gaps:79 ± 48 μm, internal gaps:51 ± 44 μm) (P<0.001). For the one-piece zirconia abutments, the SGZ-A group(18.5 ± 5.5 μm) demonstrated a significantly smaller gap between the abutment and the implant analog compared to the Lava-A group(26.5 ± 10.0 μm) (P = 0.044). No significant difference was observed among SGZ-A, SGZ-Ti and Lava-Ti groups (P>0.05). SGZ abutments demonstrate superior adaptation compared to conventional milled zirconia abutments at both the Ti base-abutment interface and the implant-abutment interface. The adaptation of one-piece SGZ abutments is comparable to that of prefabricated Ti-base abutments.


Reference:

Li, R., Liu, Y., Sun, J. et al. Adaptation assessment of all-ceramic self-glazed versus conventional zirconia implant abutments. BMC Oral Health 25, 1158 (2025). https://doi.org/10.1186/s12903-025-06572-4



Keywords:

Self-glazed, zirconia, Abutments, Superior, Fit, Over, Conventional , Zirconia, Abutments, finds, study, 3D gel deposition, Zirconia, Abutment, Implant-supported restoration, Adaptation




Tags:    
Article Source : BMC Oral Health

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News