Ultrasonography useful Noninvasive Method for Assessing Keratinized Mucosal Width at dental Implant Sites
Ultrasonography useful Noninvasive Method for Assessing Keratinized Mucosal Width at Implant Sites suggests a new study published in the Journal of Periodontology
Peri-implant keratinized mucosa (KM) has been put forth as having a protective role against peri-implant disease, and it is essential for esthetic outcomes. Traditionally, keratinized mucosa width (KMW) has been linearly assessed by using periodontal probes, which may not be highly accurate and cannot reflect the keratinized tissue volume in thick and bulky soft tissue. In this study, a non-ionizing, high-frequency, and real-time ultrasound device was used to examine the KMW changes between baseline and 12 months after soft tissue augmentation at 28 implant sites exhibiting peri-implant soft tissue dehiscence. High-frequency ultrasonography (HFUS) has been demonstrated to be highly accurate in assessing periodontal and peri-implant structures compared with histology and CBCT measurements in recent years. In this study, the KMW was assessed based on the echointensity of the keratinized epithelium, and that result was compared with the clinical measurement by a periodontal probe. In other words, the keratinized epithelium was visualized as a thick hyperechoic line on the ultrasound scans and can be discriminated from the alveolar mucosa, which lacks a hyperechoic border. In particular, this method has the advantage of visualizing the increased profile (volume) of the augmented soft tissue. In the resulting analyses, HFUS linear assessment showed a similar KMW to that shown with the clinical assessment by a periodontal probe, both at baseline and 12 months. The KM profile (surface distance from soft tissue margin to the alveolar mucosa) assessed by HFUS at 12 months was significantly greater than that determined with linear measurements by HFUS and periodontal probe. The greater the mucosa thickness (MT), the greater the difference was between surface distance and linear measurements by HFUS. The authors concluded that, in cases with augmented soft tissue with MT >2.51 mm, the linear measurements by HFUS (or by the probe) can underestimate the KM width by >1 mm. Although dental ultrasonography by far has limited popularity due to its learning curve and high cost, with the growing interest in peri-implant phenotype modification among the clinical research community, HFUS undoubtedly provides a unique tool to accurately evaluate the KW gain by assessing the soft tissue profile (volume) in addition to linear measurement.
Reference:
Tavelli, L, Yu, N, Mancini, L, Barootchi, S. Keratinized mucosa width assessment at implant sites using high-frequency ultrasonography. J Periodontol. 2023; 1- 11. https://doi.org/10.1002/JPER.23-0014
Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.
NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.