Ultrasonography useful Noninvasive Method for Assessing Keratinized Mucosal Width at dental Implant Sites

Written By :  Dr. Shravani Dali
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2023-04-17 14:30 GMT   |   Update On 2023-04-17 14:30 GMT

Ultrasonography useful Noninvasive Method for Assessing Keratinized Mucosal Width at Implant Sites suggests a new study published in the Journal of Periodontology

Peri-implant keratinized mucosa (KM) has been put forth as having a protective role against peri-implant disease, and it is essential for esthetic outcomes. Traditionally, keratinized mucosa width (KMW) has been linearly assessed by using periodontal probes, which may not be highly accurate and cannot reflect the keratinized tissue volume in thick and bulky soft tissue. In this study, a non-ionizing, high-frequency, and real-time ultrasound device was used to examine the KMW changes between baseline and 12 months after soft tissue augmentation at 28 implant sites exhibiting peri-implant soft tissue dehiscence. High-frequency ultrasonography (HFUS) has been demonstrated to be highly accurate in assessing periodontal and peri-implant structures compared with histology and CBCT measurements in recent years. In this study, the KMW was assessed based on the echointensity of the keratinized epithelium, and that result was compared with the clinical measurement by a periodontal probe. In other words, the keratinized epithelium was visualized as a thick hyperechoic line on the ultrasound scans and can be discriminated from the alveolar mucosa, which lacks a hyperechoic border. In particular, this method has the advantage of visualizing the increased profile (volume) of the augmented soft tissue. In the resulting analyses, HFUS linear assessment showed a similar KMW to that shown with the clinical assessment by a periodontal probe, both at baseline and 12 months. The KM profile (surface distance from soft tissue margin to the alveolar mucosa) assessed by HFUS at 12 months was significantly greater than that determined with linear measurements by HFUS and periodontal probe. The greater the mucosa thickness (MT), the greater the difference was between surface distance and linear measurements by HFUS. The authors concluded that, in cases with augmented soft tissue with MT >2.51 mm, the linear measurements by HFUS (or by the probe) can underestimate the KM width by >1 mm. Although dental ultrasonography by far has limited popularity due to its learning curve and high cost, with the growing interest in peri-implant phenotype modification among the clinical research community, HFUS undoubtedly provides a unique tool to accurately evaluate the KW gain by assessing the soft tissue profile (volume) in addition to linear measurement.

Reference:

Tavelli, L, Yu, N, Mancini, L, Barootchi, S. Keratinized mucosa width assessment at implant sites using high-frequency ultrasonography. J Periodontol. 2023; 1- 11. https://doi.org/10.1002/JPER.23-0014

Tags:    
Article Source : Journal of Periodontology

Disclaimer: This site is primarily intended for healthcare professionals. Any content/information on this website does not replace the advice of medical and/or health professionals and should not be construed as medical/diagnostic advice/endorsement/treatment or prescription. Use of this site is subject to our terms of use, privacy policy, advertisement policy. © 2024 Minerva Medical Treatment Pvt Ltd

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News