Hybrid closed-loop insulin therapy effectively improves blood sugar control in T1D
log Rochelle, NY- Despite improvements in care, a majority of youth with type 1 diabetes still fail to meet blood sugar control targets.
Hybrid closed-loop insulin therapy improved blood sugar control in adolescents and young adults with type 1 diabetes finds an International Diabetes Closed-Loop (iDCL) Trial.
The findings are reported in the peer-reviewed journal Diabetes Technology & Therapeutics (DTT).
Researchers conducted a new study to assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes.
Adolescents and young adults with a mean age of 17 years were randomly assigned to a closed-loop control (CLC) insulin delivery system or a sensor augmented pump (SAP) with a continuous glucose monitoring system over a 6-month period. The Time in Range increased by 13% for the CLC group, compared to a decrease of 1% with SAP, for a group difference of +3.1 hours/day. This reflected a reduction in time spent at >180 mg/dL. The use of CLC was especially effective at increasing Time in Range overnight.
"Notably, we found that this sample of adolescents and young adults successfully used the CGM more than 90% of the time during the 6-month trial and the closed-loop system was active 89% of the time," stated John Lum, Jaeb Center for Health Research, and the iDCL Trial Research Group.
The researchers concluded that use of closed-loop control for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, closed-loop control has the potential to improve blood sugar outcomes in this challenging age group.
"Multiple Automated Insulin Delivery (AID) systems using different algorithms have been developed in the past decade for patients with type 1 diabetes. Almost all of the systems have shown significant reductions in nocturnal hypoglycemia. The iDCL multicenter trial done in young adults and adolescents with T1D reported in this issue of DTT further advances the use of hybrid closed-loop system by increasing the time-in-range, especially during the night," says Satish Garg, MD, University of Colorado Denver and Editor-in-Chief of Diabetes Technology & Therapeutics.
https://www.liebertpub.com/doi/10.1089/dia.2020.0572
Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.