Cooler dialysate did not substantially lower the likelihood of serious CV events during Hemodialysis : LANCET

Written By :  Dr. Kamal Kant Kohli
Published On 2023-01-02 04:00 GMT   |   Update On 2023-01-02 06:04 GMT

Canada: The cluster-randomized MyTEMP study, presented at the American Society of Nephrology Kidney Week and reported in The Lancet, found no cardiovascular (CV) gains from using a cooler dialysate during maintenance hemodialysis. Hemodialysis centers have traditionally treated all patients to maintenance hemodialysis at a constant dialysate temperature, such as 36°C. For possible...

Login or Register to read the full article

Canada: The cluster-randomized MyTEMP study, presented at the American Society of Nephrology Kidney Week and reported in The Lancet, found no cardiovascular (CV) gains from using a cooler dialysate during maintenance hemodialysis.

Hemodialysis centers have traditionally treated all patients to maintenance hemodialysis at a constant dialysate temperature, such as 36°C. For possible cardiovascular benefits, many centers now utilize dialysate that is cooler (e.g., 36°C or lower).

The authors sought to determine whether personalized cooler dialysate, applied as a center-wide policy, decreased the likelihood of hospital admission or death owing to cardiovascular disease.

A pragmatic, two-arm, parallel-group, registry-based, open-label, cluster-randomized superiority trial called MyTEMP was conducted at dialysis facilities in Ontario, Canada.

The medical director of each eligible center had to certify that the center will carry out the designated intervention. Eligible centers required to provide maintenance haemodialysis to at least 15 patients per week. They distributed 84 centers in a 1:1 ratio to either utilize individualized cooler dialysate or standard temperature dialysate (36.5°C for all patients and treatments) using covariate-constrained randomization. Over the course of the 4-year trial, the main composite outcome was cardiovascular-related death or hospital admission with myocardial infarction, ischemic stroke, or congestive heart failure. Analysis was done with the purpose to treat.

Key findings of the trial:

  • In comparison to patients who received a standard temperature dialysate (average 36.4°C), patients who received a cooler dialysate temperature (average 35.8°C) did not have a significantly higher risk of a composite outcome of CV-related death or hospital admission with myocardial infarction, ischemic stroke, or congestive heart failure.
  • The primary endpoint of the trial was missed because it happened in 21.4% of the group receiving cooler dialysate compared to 22.4% of the group receiving dialysate at room temperature (adjusted HR 1.00, 96% CI 0.89-1.11, P=0.93).
  • Throughout the 4-year experiment, there were no differences in any of the various components of the primary composite outcome.
  • Systolic blood pressure (BP), a crucial secondary outcome, wasn't significantly impacted by administering a cooler dialysate.
  • In the cooler group, the intradialytic systolic blood pressure dropped on average by 26.6 mmHg compared to 27.1 mmHg in the usual temperature group (mean difference -0.5 mmHg, 99% confidence interval -1.4 to 0.4, P=0.14).
  • patients weren't satisfied with their customized cooler dialysate because those who received the cooler were much more likely to report feeling extremely cold than those who received the standard temperature (relative risk 1.6, 99% CI 1.1-2.5).

According to Amit Garg, MD, PhD, of Victoria Hospital in London, Ontario, Canada, and colleagues, "this analysis calls into question the growing popularity of cooler dialysate and suggests that future trials should clarify the hazards and advantages of cooler dialysate in particular patient populations."

Although they acknowledged MyTEMP as "impressive," they concluded that its results "should not be taken as definite evidence that cooling the dialysate is unsuccessful for specific patients."

REFERENCE

MyTEMP writing committee "Personalised cooler dialysate for patients receiving maintenance haemodialysis (MyTEMP): a pragmatic, cluster-randomised trial" Lancet 2022; DOI: 10.1016/ S0140-6736(22)01805-0. 

Tags:    
Article Source : The Lancet

Disclaimer: This site is primarily intended for healthcare professionals. Any content/information on this website does not replace the advice of medical and/or health professionals and should not be construed as medical/diagnostic advice/endorsement/treatment or prescription. Use of this site is subject to our terms of use, privacy policy, advertisement policy. © 2024 Minerva Medical Treatment Pvt Ltd