B scan US and eye-steering UWFI combo useful tool for retinal tear detection prior to cataract surgery, finds study

Published On 2024-05-24 15:45 GMT   |   Update On 2024-05-25 06:27 GMT
Advertisement

B scan US and eye-steering UWFI combo useful tool for retinal tear detection prior to cataract surgery, finds a study published in the Retina.

A study was done to investigate the efficacy of combined application of B-scan ultrasonography (US) and ultrawide field imaging (UWFI) in detecting retinal tears before cataract surgery. Of 1,277 cataract patients, 2,552 eyes were enrolled and received both B-scan US and UWFI examinations preoperatively. Three types of combination were applied: type 1 (union, B-scan US or centered UWFI), type 2 (intersection, B-scan US and centered UWFI), and type 3 (B-scan US and eye-steering UWFI). Sensitivity and specificity of detecting retinal tears by different methods were assessed. Results: Totally 4.55% (116/2,552) of eyes were presented with retinal tears. The sensitivity of B-scan US and UWFI was 87.93% and 84.48%, and specificity was 95.16% and 99.79%, respectively. By applying type 1 and type 2 combination, the sensitivity was 98.28% and 74.14%, and specificity was 95.03% and 99.92%, respectively. By type 3 combination, the sensitivity increased to 95.69% and specificity to 99.88%, both of which were comparable to indirect ophthalmoscopy regardless of the number, type, and location of tears (P > 0.05). In eyes with any cataract type or axial length, type 3 combination also gained comparable performance to indirect ophthalmoscopy. Combined application of B-scan US and eye-steering UWFI presented satisfactory performance in detecting retinal tears before cataract surgery.

Advertisement

Reference:

Meng, Jiaqi, Cheng, Kaiwen MS*,†,‡; Huang, Zhiqian MS*,†,‡; He, Wenwen MD*,†,‡; Zhang, Keke MD*,†,‡; Lu, Yi MD*,†,‡; Zhu, Xiangjia MD*,†,‡,§. COMBINED APPLICATION OF B-SCAN ULTRASONOGRAPHY AND EYE-STEERING ULTRAWIDE FIELD IMAGING TO IMPROVE THE DETECTION OF RETINAL TEARS BEFORE CATARACT SURGERY. Retina 44(5):p 810-819, May 2024. | DOI: 10.1097/IAE.0000000000004040


Keywords:

B scan, US, eye-steering, UWFI, combo, useful tool, retinal tear, detection, cataract surgery, study, Meng, Jiaqi, retina





Tags:    
Article Source : Retina

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News