Use of antiepileptic Drugs increases risk of hip fracture in Alzheimer's Disease: Study
According to a recent study published in the Journal of Clinical Epidemiology, it has been observed that antiepileptic drugs (AED) use is associated with an increased risk of hip fracture in people with Alzheimer´s disease (AD).
Hip fractures are indeed a major health problem in older adults, and strongly affect their health and well-being, substantially increasing morbidity, short-term mortality, and reducing autonomy and quality of life. As a result, health-care costs are also substantially increased.
Hence, Pisa F, Reinold J and associates from the School of Pharmacy, University of Eastern Finland, Kuopio, Finland carried out this study to determine the risk of hip fracture in persons with Alzheimer´s disease (AD) who initiated antiepileptic drugs (AEDs).
This cohort of 70,719 Finnish community dwellers with clinically verified incident AD diagnosis were identified and registered for the study. AEDs were classified as older (valproate, carbamazepine, clonazepam, phenytoin, levetiracetam, primidone) or newer (pregabalin, gabapentin, oxcarbazepine, lamotrigine, topiramate). The authors further matched each user to 2 non-users. Incident hip fractures were identified from the Care register for health care. The inverse probability of treatment weighted hazard ratios (HR), with 95% confidence intervals, using Cox regression was calculated.
The following facts were observed-
- Altogether 5522 incident users were identified and matched to 11,044 non-users (in both groups, women: 65%; median age: 81 years).
- Altogether 53.3% of users initiated with newer AEDs (pregabalin 79.8%, gabapentin 10.2%) while 46.7% initiated with older AEDs (valproate 67.6%, carbamazepine 13.0%).
- Age- and sex-adjusted IR of hip fracture per 100 person-years was 1.8 (95% CI 1.6– 1.9) in non-users and 2.0 (95% CI 1.8– 2.2) in users.
- Increased risk of hip fracture was observed in users (HR 1.17, 95% CI 1.05– 1.30) compared with non-users.
- The risk was higher for short duration of use (< 14 weeks, HR 3.64, 95% CI 2.90– 4.58) than for medium duration (14 to < 64 weeks, HR 1.74, 95% CI 1.48– 2.05) or ≥ 64 weeks' use (HR 1.23, 95% CI 1.08– 1.40), compared to non-users with same follow-up time.
- Older AEDs had HR of 1.46 (1.03– 2.08) compared with newer AEDs.
Hence, the authors concluded that "AED use is associated with an increased risk of hip fracture in people with AD."
These findings prompt careful consideration before prescribing AEDs to persons with AD. Persons with AD treated with antiepileptics should be carefully monitored due to their increased risk of falling and fractures, they further added.
Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.
NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.