Dual-energy CT (DECT) is an exciting innovation in CT technology with profound capabilities to improve diagnosis and add value to patient care. A recent review article has recommended the radiologists and technologists to be aware of technological principles that may cause artifacts at dual-energy CT so that they can apply strategies to mitigate their occurrence and avoid diagnostic misinterpretation. The review report was published in the journal RadioGraphics on February 19, 2021.

Advertisement

DECT is a tremendous innovation in CT technology that allows the creation of numerous imaging datasets by enabling discrete acquisitions at more than one energy level. Technological advances and the proliferation of various processing methods have led to the availability of diverse vendor-based DECT approaches, each with a different acquisition and image reconstruction process.

The authors wrote in the report, "To enable effective use of DECT, one must be aware of the pitfalls and artifacts related to this technology." They further added, "The ability of radiologists and technologists to anticipate their (artifacts)occurrence and provide recommendations for proper selection of patients, intravenous and oral contrast media, and scan acquisition parameters are key to obtaining good-quality DECT images."

The team addressed radiologists to consider the following considerations when performing the DECT exams:

  • Patient selection. Optimize DECT protocols by taking patient body weight and transverse diameter into consideration. "In patients with large body habitus, DECT may yield higher image noise and reduced image quality due to photon starvation," the team noted.
  • Contrast medium selection. The appearance of iodine contrast appearance can be amplified on DECT, appearing as streaks on the image; reducing the iodine concentration in the contrast medium may be needed.
  • Patient positioning. "Patients may need to be purposely off-centred to ensure that the organ of interest lies completely within the spectral field of view," the group cautioned.
  • Temporal misregistration. This can affect image quality and lead to "spectral skew," in which data from the two energies being used are offset from each other.
  • Image processing. Carefully select kernel, decomposition ratio, and thresholding parameters, the team wrote.
  • Image display. Wider window settings are often needed to view DECT images.

The commentatorwrote, "This article serves our community well in providing a high-level view of common DECT-related artifacts and makes a strong case that vendor-specific mitigation approaches must be considered."

For further information:

https://pubs.rsna.org/doi/10.1148/rg.2021200049


Tags:    
Article Source :  RadioGraphics 

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News