Mumbai: Taking note of the complaints regarding unqualified technicians and questionable materials used in dental aids, the Maharashtra Government has issued guidelines to regulate dental laboratories, technicians, manufacturers, and suppliers.
In its resolution dated November 6, 2026, the State Government has also ordered inspections by the Food and Drug Administration to ensure compliance.
According to an Indian Express report, the Medical Education Department of Maharashtra has received more than 350 complaints since 2014, raising concerns regarding unqualified people undertaking dental laboratory work and the use of inferior materials. Commenting on this, Dr. Pallavi Saple, the Director of Medical Education and Research, said that this is mainly due to a shortage of trained personnel. Even though Maharashtra has around 66,000 registered dentists, there are only around 1,200 qualified dental technicians.
Guidelines issued by the Maharashtra Government:
In the order dated 06.11.2026, the Medical Education Department of Maharashtra mentioned that dentists take the assistance of dental technicians and dental laboratories for preparing artificial teeth, dentures, crowns, bridges, prosthetic structures on dental implants, appliances used for straightening teeth, and other restorative and dental appliances required for the oral healthcare treatment of patients.
The Government clarified in the order that such work must be carried out according to the medical requirements of the patient, based on the examination conducted by the dentist and in accordance with the written or electronic instructions issued by the dentist.
In the order, the Government pointed out that certain instances had come to notice where dental technicians accept work directly without written prescriptions or authorised instructions from dentists, prescribed technical standards are not followed, inferior-quality or unsuitable materials are used, necessary hygiene and sterilisation procedures are not followed, and essential records relating to the quality of work are not maintained.
Highlighting that such practices may result in improper fabrication of artificial teeth and dental appliances, diseases affecting oral tissues, risk of infection, allergies, or other adverse effects.
To protect the oral health of patients in Maharashtra and ensure that dental appliances are manufactured in accordance with the instructions of dentists, and to establish uniform procedures regarding minimum infrastructure, hygiene, sterilisation, quality of materials and record management for the functioning of dental technicians and dental laboratories, the Government has issued the following guidelines:
Prescription by Dentist:
(1) Artificial teeth, dentures, crowns, bridges, prosthetic structures on dental implants, appliances used for straightening teeth and other appliances manufactured by dental laboratories shall be fabricated only on the basis of written prescriptions or electronic instructions issued by a dentist.
(2) The name and registration number of the dentist, the patient's reference number, the type of appliance, the material to be used, the shade and the necessary technical specifications must be mentioned on the prescription.
(3) A dental technician shall not interfere in the scope of the dentist's medical diagnosis, treatment planning or treatment, and shall not accept work directly from patients.
Manufacturing Licence:
(4) All manufacturers in the State engaged in the fabrication/manufacture of dental appliances that are covered under the Medical Devices Rules, 2017 and classified as medical devices by CDSCO shall obtain the prescribed licence from the competent licensing authority, according to the risk classification of the device, before commencing manufacturing.
(5) The risk classification of the device shall be determined according to the dental-device classification list notified by CDSCO. In case of any doubt, the concerned party shall seek guidance from the Food and Drug Administration.
Licence for Sale and Distribution:
(6) All vendors, distributors and suppliers engaged in the sale, stocking, exhibition, offering for sale or distribution of dental medical devices, as well as materials in the form of medical devices used in dental laboratories (for example, artificial teeth, denture base resin, dental alloys, ceramics, dental cement, impression materials and implant components), shall be required to apply to the State Licensing Authority in Form MD-41 and obtain a registration certificate in Form MD-42, in accordance with the notification mentioned at Reference No. 6 above (except where a prescribed exemption applies).
For imported devices, the importer must possess an import licence in Form MD-15 issued by the Central Licensing Authority.
Procurement by Dentists from Licensed Sources:
(7) Every dentist shall purchase dental medical devices and materials only from manufacturers/importers holding valid manufacturing/import licences or from vendors holding a valid sale registration certificate (Form MD-42) or other applicable licence.
(8) At the time of purchase, dentists must ensure that the purchase invoice mentions the licence or registration number of the vendor/manufacturer, the name of the device, the name of the manufacturer, the batch/lot/serial number, and the manufacturing and expiry dates.
(9) The batch/lot/serial number and supplier details of the device used on a patient (particularly dental implants and laboratory-manufactured appliances) must be recorded in the patient's treatment records so that traceability is ensured in the event of a device recall or an adverse event.
(10) Unlabelled devices, devices with incomplete labels, expired devices, devices without licence numbers or suspicious devices shall not be purchased or used. Such instances must be reported to the Food and Drug Administration.
Compliance with Labelling Provisions:
(11) Manufacturers, importers and dental laboratories shall be required to comply with the labelling provisions specified under Rule 44 of the Medical Devices Rules, 2017.
(12) Vendors and dentists shall ensure, at the time of purchase, that the products comply with the labelling rules.
Compliance with the Provisions of the Medical Devices Rules, 2017:
(13) Dental laboratories shall maintain the following records:
(a) Receipt of raw materials, name of supplier, licence/registration number, invoice and batch number;
(b) Prescriptions/instructions received;
(c) Manufacturing and quality inspection records;
(d) Sterilisation records;
(e) Dispatch records; and
(f) Records of complaints and action taken thereon.
They shall also comply with the provisions of the Medical Devices Rules, 2017.
Adverse Events and Device Recalls:
(14) Serious adverse events arising from the use of dental appliances shall be reported by dentists, dental laboratories and manufacturers to the Materiovigilance Programme of India (MvPI), implemented through the Indian Pharmacopoeia Commission, and to the Food and Drug Administration.
(15) The orders issued by the competent authority for recalling any device shall be complied with immediately.
Inspection and Legal Action:
(16) Drug Inspectors of the Food and Drug Administration are empowered under Section 22 of the Drugs and Cosmetics Act, 1940 and the Medical Devices Rules, 2017 to inspect dental laboratories, vendors and dental establishments, and to collect samples under Section 23.
(17) If manufacture/sale without a licence (Section 18(c)), misbranded, adulterated or spurious devices (Sections 17, 17A and 17B) are found, legal action shall be initiated against the concerned persons under Section 27 of the Act.
(18) Further, if registered dentists and dental technicians violate these directions, disciplinary action shall be initiated through the Maharashtra State Dental Council under the Dentists Act, 1948 and the National Dental Commission Act, 2023.
The order mentioned that Compliance with the Dentists Act, 1948, the relevant rules, the National Dental Commission Act, 2023 and the applicable provisions thereunder, the Drugs and Cosmetics Act, 1940 and the rules framed thereunder, the Medical Devices Rules, 2017, the Biomedical Waste Management Rules, 2016, and other applicable laws and directions issued by the competent authorities shall be mandatory for all concerned entities.
Amendments made by the Central Government to these rules from time to time shall automatically apply to this Government Resolution, it further added.
It has been further stated in the order that in accordance with the directions dated 13 October 2026 issued by the Ethics and Dental Registration Board of the National Dental Commission, services relating to dental laboratories shall be obtained from or assigned only to dental technicians who possess dental educational qualifications recognised by the Dental Council of India or the National Dental Commission. Further, such dental technicians must have valid, updated and active registration with the Dental Council of any State in the country.
All registered dental practitioners shall ensure that dental prosthetic appliances, dental instruments and all other work related to dental laboratories referred by them are manufactured or completed only by qualified and registered dental technicians who fulfil the prescribed standards, the order said, further adding that engaging unregistered or unqualified persons or laboratories for the services of dental technicians shall be considered a violation of the professional standards prescribed by the National Dental Commission.
Commenting on the Government action, Medical Education Minister Hasan Mushrif told Indian Express that the move was intended to protect patients. “It is for the betterment of patients. They should get standardised material. Dentists also have to be careful and ensure that they provide patients with standard material,” he said.
Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.
NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.