Modified INFIX combined with sacroiliac joint screws safe and effective for pelvic instable injuries

Written By :  Dr. Shravani Dali
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2023-12-21 02:45 GMT   |   Update On 2023-12-21 08:56 GMT

C-INFIX safe with low complication rates among patients with pelvic unstable injuries suggests a new study published in the BMC Surgery.The INFIX technique is becoming one of the most commonly performed surgical procedures for anterior pelvic ring instability injuries. The purpose of this article is to compare the clinical outcomes of modified anterior subcutaneous internal fixation...

Login or Register to read the full article

C-INFIX safe with low complication rates among patients with pelvic unstable injuries suggests a new study published in the BMC Surgery.

The INFIX technique is becoming one of the most commonly performed surgical procedures for anterior pelvic ring instability injuries. The purpose of this article is to compare the clinical outcomes of modified anterior subcutaneous internal fixation (M-INFIX) with conventional anterior subcutaneous internal fixation (C-INFIX) for anterior pelvic ring instability injuries.

A retrospective analysis of 36 cases of unstable pelvic injuries treated operatively at our institution, 20 of which were treated with C-INFIX and 16 with M-INFIX. Data collected included age, gender, ISS score, fracture typing, operative time, operative bleeding, postoperative complications, fracture healing time, Matta score, Majeed score, and follow-up time. Statistical sub-folding of each variable between the two groups was performed.

Results

There was no statistical difference between the C-INFIX and M-INFIX groups in terms of age, gender, ISS (Injury Severity Score), follow-up time, fracture typing, fracture healing time, and Majeed score (P > 0.05). the M-INFIX had a significantly lower incidence of postoperative complications than the C-INFIX group, especially in the incidence of Lateral femoral cutaneous nerve (LFCN) injury (P < 0.05). In contrast, the M-INFIX group had statistically higher operative time, intraoperative bleeding, and Matta score than the C-INFIX group (P < 0.05).

This study was based on a modified application of the surgical experience with C-INFIX and showed better clinical outcomes in terms of complication rates and quality of repositioning than the conventional surgical approach. These findings indicate that further analytical studies of this study would be valuable.

Reference:

Zhao, P., Li, R., Liu, L. et al. Clinical study of modified INFIX combined with sacroiliac joint screws for pelvic instable injuries. BMC Surg 23, 350 (2023). https://doi.org/10.1186/s12893-023-02205-1

Keywords:

C-INFIX, safe, low, complication, rates, among, patients, pelvic, instable, injuries,BMC Surgery, Zhao, P., Li, R., Liu, L.

Tags:    
Article Source : BMC Surgery

Disclaimer: This site is primarily intended for healthcare professionals. Any content/information on this website does not replace the advice of medical and/or health professionals and should not be construed as medical/diagnostic advice/endorsement/treatment or prescription. Use of this site is subject to our terms of use, privacy policy, advertisement policy. © 2024 Minerva Medical Treatment Pvt Ltd

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News