Positive-Pressure Exhaust Technique Improves Mesh Fixation in TAPP Hernia Repair: Study
Researchers have found in a study on laparoscopic transabdominal preperitoneal (TAPP) hernia repair that the pneumoperitoneum positive-pressure exhaust technique enhances mesh fixation by eliminating dead space and improving tissue apposition.
This simple, cost-effective approach may lower recurrence risk and offers benefits such as real-time mesh positioning assessment, multimodal fixation without extra devices, and simplified dead space management. Further large-scale studies are needed to validate its long-term efficacy.
A study was done to investigate the effects of the pneumoperitoneum positive-pressure exhaust technique on mesh fixation and postoperative recovery in laparoscopic transabdominal preperitoneal prosthetic (TAPP) hernia repair.
A retrospective cohort analysis was conducted on 655 patients who underwent TAPP between January 2019 and December 2023. Patients were divided into a direct suture group (n=304) and a positive-pressure exhaust group (n=351) on the basis of preperitoneal space management. In the exhaust group, a 20G needle or drainage tube was placed percutaneously before peritoneal closure. After suturing, 12 mmHg pneumoperitoneum pressure was maintained to evacuate residual gas from the preperitoneal space through the externalized needle/tube. The primary outcomes included postoperative complications (bleeding, mesh infection, seroma, reoperation) and hospitalization duration.
Results: Baseline characteristics were not significantly different (P>0.05). Although not statistically significant, there were clinically meaningful differences between the groups; the exhaust group had lower seroma (11.97% vs. 16.78%, P=0.079) and mesh infection (0.28% vs. 1.32%, P=0.189) incidence rates than the direct suture group did. The exhaust group had a significantly shorter hospital stay than the direct suture group (median 7 vs. 7 days, P=0.013) and had a 0% recurrence rate at the 1-year follow-up (vs. 1.32% for the direct suture group).
The positive-pressure exhaust technique facilitates mesh fixation by eliminating dead space through improved tissue apposition. This simple, cost-effective approach may reduce the risk of recurrence, although larger prospective studies are needed to validate its long-term efficacy.
Reference:
He, W., Chen, B. Efficacy of intraperitoneal positive pressure gas expulsion in laparoscopic transabdominal preperitoneal hernioplasty: a retrospective cohort study. BMC Surg 25, 231 (2025). https://doi.org/10.1186/s12893-025-02965-y
Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.