- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
CGM Superior to Routine Care in Non-Insulin Type 2 Diabetes: NEJM

A multi-center randomized control trial conducted at various primary care practices in the United States investigating continuous glucose monitoring (CGM) devices in people with non-insulin type 2 diabetes has been a significant contributor to wearables’ advancement as health devices. The study found that adults with non-insulin type 2 diabetes who were under treatment in primary care practices exhibited lower levels of glycated hemoglobin and were less likely to be at a risk of high blood sugar when using CGM devices compared to the group receiving conventional treatment. The study was published in The New England Journal of Medicine by Tamara K. and colleagues.
For assessment of the clinical effectiveness of CGM relative to control group receiving the current standard of care, a prospective 26-week randomized controlled trial was carried out across 22 primary care practices in the United States. In all, 283 adults suffering from type 2 diabetes and not under any form of insulin treatment were randomly assigned into two groups, group under the regimen of CGM (n = 145) and group receiving routine care through fingerstick self-measurement (n = 138). Participants were from varied age groups of 21 to 84 years.
The primary efficacy end-point was determined as the difference in HbA1c between the treatment arms after 26 weeks of randomization. The following secondary end-points were assessed via CGM using the hierarchical testing approach in order to minimize type I error rate: glucose levels in the range of 70–180 mg/dL, as well as hypoglycemic parameters (70 and 54 mg/dL) during nighttime and daytime periods.
Key findings:
- Detailed statistical analysis among the 283 randomized subjects revealed superior efficacy of continuous glucose monitoring over the standard routine treatment regarding glycemic management.
- The CGM group witnessed a statistically significant reduction in the levels of glycated hemoglobin from 8.8 ± 1.3% at baseline to 7.2 ± 1.1% at 26 weeks compared to a slight reduction in patients with the routine treatment from 8.7 ± 1.2% to 8.0 ± 1.4% (adjusted mean difference −0.9 percentage points; 95% CI, −1.1 to −0.6; P < 0.001).
- Mean percentage time the glucose stayed in a desired range between 70 to 180 mg/dL was 21 percentage points higher in CGM group than in the routine group (95% CI, 16 to 26, P < 0.001).
- Percentage difference of the time the glucose stayed below 54 mg/dL was −0.17 percentage points (95% CI, −0.27 to −0.11; P < 0.001 for noninferiority).
- Difference in time staying below 70 mg/dL was −0.20 percentage points (95% CI, −0.43 to −0.09; P < 0.001 for noninferiority; P = 0.004 for superiority).
- There were no severe hypoglycemia incidents in either of the treatment groups.
In summary, from the 26-week multicenter study, it is evident that continuous glucose monitoring offers improved glycemic control relative to standard of care using finger stick measurements in type 2 diabetics not on insulin therapy. The major conclusions drawn from this study are that continuous monitoring decreases HbA1c and reduces hyperglycemia exposure.
Reference:
Oser, T. K., Martens, T., Ruedy, K. J., Bergford, S., Calhoun, P., Chang, K.-L., Kramer, E. S., Klug, B. A., Anderson, R. L., Cook, B. R., Pickering, D., Ortega, M., Peterson, B., Davidson, L., Schmid, R., Desai, N. D., Burkett, E., Haynes, J. L., Herman, A., … Beck, R. W. (2026). Continuous glucose monitoring in non–insulin-treated type 2 diabetes. New England Journal of Medicine. https://doi.org/10.1056/nejmoa2608571
Dr Riya Dave has completed dentistry from Gujarat University in 2022. She is a dentist and accomplished medical and scientific writer known for her commitment to bridging the gap between clinical expertise and accessible healthcare information. She has been actively involved in writing blogs related to health and wellness.
Dr Kamal Kant Kohli-MBBS, DTCD- a chest specialist with more than 30 years of practice and a flair for writing clinical articles, Dr Kamal Kant Kohli joined Medical Dialogues as a Chief Editor of Medical News. Besides writing articles, as an editor, he proofreads and verifies all the medical content published on Medical Dialogues including those coming from journals, studies,medical conferences,guidelines etc. Email: drkohli@medicaldialogues.in. Contact no. 011-43720751