- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
SCUBA divers with PFO at higher risk for decompression illness - Video
Overview
A study of a cohort of SCUBA divers has found that the presence of high-risk patent foramen ovale (PFO), or a hole in the heart, was associated with an increased risk of decompression illness (DCI), also commonly known as the bends. The authors recommend that divers with high-risk PFO should consider either refraining from diving or adhering to a conservative diving protocol.
DCI is a disease in which inhaled nitrogen is dissolved in tissues or blood under a high pressure during a diver’s descent and subsequently forms gas bubbles while they rise, mechanically affecting the tissue or inhibiting blood flow. A PFO enables venous nitrogen bubbles to embolize into the arterial system.
Researchers from Sejong Hospital, Bucheon, South Korea conducted a prospective cohort study of 100 experienced divers who did more than 50 dives per year. Participants had transesophageal echocardiography with a saline bubble test to determine the presence of a PFO and were subsequently divided into high- and low risk groups. They were followed up using a self-reported questionnaire while blinded to their PFO status. The authors report that 12 of 68 divers with PFO (10 of 37 divers with high-risk PFO) experienced DCI.
Ref:Annals of Internal Medicine, https://www.acpjournals.org/doi/10.7326/M23-0260
Speakers
Isra Zaman
B.Sc Life Sciences, M.Sc Biotechnology, B.Ed