- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
Implantation of Signus ROTAIO-Prosthesis maintains ROM in cervical spine and results in physiological iCOR
The new trend is towards motion-preserving surgical procedures, such as cervical total disc replacement (cTDR). The aim of this technique is to replace the intervertebral disc, releasing and decompressing the corresponding nerve roots while maintaining and restoring segmental and overall range of motion (ROM).
The instantaneous center of rotation (iCOR) of a motion segment has been shown to correlate with its total ROM. Importantly, a correlation of the correct placement of cTDR to preserve a physiological iCOR has been previously identified. However, changes of these parameters and the corresponding clinical relevance have hardly been analyzed.
Anna Lang et al conducted a study to assesses the radiological and clinical correlation of iCOR and ROM following cTDR. The article has been published in ‘European Spine Journal.’
The ROTAIO® prosthesis is an unconstrained prosthesis enabling an uncoupled translation of the vertebral bodies with a variable center of rotation. The special design is intended to mimic physiological motion of the index segment aiming to reduce the biomechanical load on the adjacent levels.
A retrospective multi-center observational study was conducted and radiological as well as clinical parameters were evaluated preoperatively and 1 year after cTDR with an unconstrained device. Radiographic parameters including flexion/extension X-rays (fex/ex), ROM, iCOR and the implant position in anterior–posterior direction (IP ap), as well as corresponding clinical parameters [(Neck Disability Index (NDI) and the visual analogue scale (VAS)] were assessed.
Key findings of the study:
• The authors analyzed 53 patients treated with a uni- or bilevel cTDR from 5 different neurosurgical centers.
• 49 patients (92.5%) received a one level cTDR and 4 patients (7.5%) were treated by two-level cTDR.
• 32 females (60.4%) and 21 males (39.6%) with a mean age of 47.4 years (range: 27–65 years) received a ROTAIO® prosthesis in a total of 57 index segments.
• Pre- and post-operative ROM showed no signifcant changes (8.0° vs. 10.9°; p>0.05).
• Significant correlations between iCOR and IP (Pearson’s R: 0.6; p<0.01) as well as between ROM and IP ap (Pearson’s R: − 0.3; p=0.04) were identified.
• NDI and VAS improved significantly (p<0.01).
• A significant correlation between NDI and IP ap after 12 months (Pearson’s R: − 0.39; p<0.01) was found.
The authors concluded that - Implantation of unconstrained prostheses with the opportunity of uncoupled translation maintains the physiologi cal ROM and iCOR. However, special attention should be paid on implant positioning. Accordingly, comparable data should be available for all cTDR designs, in order to improve the device function through optimal surgical handling and positioning.
Further reading:
Clinical and radiological outcome 1 year after cervical total disc replacement using the Signus ROTAIO – Prosthesis Anna Lang, Sara Lener et al European Spine Journal (2022) 31:3477–3483https://doi.org/10.1007/s00586-022-07416-3
MBBS, Dip. Ortho, DNB ortho, MNAMS
Dr Supreeth D R (MBBS, Dip. Ortho, DNB ortho, MNAMS) is a practicing orthopedician with interest in medical research and publishing articles. He completed MBBS from mysore medical college, dip ortho from Trivandrum medical college and sec. DNB from Manipal Hospital, Bengaluru. He has expirence of 7years in the field of orthopedics. He has presented scientific papers & posters in various state, national and international conferences. His interest in writing articles lead the way to join medical dialogues. He can be contacted at editorial@medicaldialogues.in.
Dr Kamal Kant Kohli-MBBS, DTCD- a chest specialist with more than 30 years of practice and a flair for writing clinical articles, Dr Kamal Kant Kohli joined Medical Dialogues as a Chief Editor of Medical News. Besides writing articles, as an editor, he proofreads and verifies all the medical content published on Medical Dialogues including those coming from journals, studies,medical conferences,guidelines etc. Email: drkohli@medicaldialogues.in. Contact no. 011-43720751