Adapting Occlusal design and adjustment may improve properties of zirconia and resin composite crowns

Written By :  Dr. Shravani Dali
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2022-11-23 14:30 GMT   |   Update On 2022-11-23 14:30 GMT
Advertisement

It is necessary to adapt occlusal design and adjustment in order to improve roughness, wear, and stability of zirconia and resin composite crowns according to a recent study published in the Journal Of Dentistry.

Researchers have conducted the study to investigate the impact of the occlusal contact situation and occlusal adjustment on wear, roughness, and fracture force of molar crowns.

CAD/CAM crowns (lower right first molar, n=64; 4 groups à 8, 3Y-TZP zirconia and resin composite) and corresponding antagonists (upper right first molar; 3Y-TZP zirconia) were manufactured. Crowns were constructed according to two principles of occlusion (group "T": Peter K. Thomas' "point-centric" cusp-to-fossa tripodization concept, with 15 contact points; group "RA" Sigurd P. Ramfjord and Major M. Ash, "freedom in centric" concept with four contacts). On one half of the crowns, occlusal adjustment was performed (groups "T adjusted" and "RA adjusted"). All crowns underwent combined thermal cycling (TC) and mechanical loading (ML) (ML: 1.2 × 106 cycles, 50 N, 2 Hz, mouth opening 1 mm; TC: 2 × 3000 cycles, 5/55°C). Wear area and depth of each contact point on the occlusal surfaces of crowns and antagonists were determined using a digital microscope. Surface roughness (Ra, Rz) was measured in and besides (reference) the worn area (3D laser-scanning microscope). Fracture force of the crowns was determined (statistics: Levene-test, one-way-ANOVA; Bonferroni-post-hoc-test; between-subjects effects, Pearson correlation, α=0.05).

Advertisement
Results
  • The resin composite crowns yielded significantly higher mean values for wear area and depth and lower fracture forces

  • Resin composite surfaces showed increased roughness after TCML while zirconia exhibited smoothened surfaces.

  • The occlusal design significantly impacted wear depth and fracture force

  • Resin composite crowns with fewer contact points (group RA) showed more wear and lower fracture force.

  • Adjusted resin composite crowns showed increased wear areas and depths

  • For zirconia crowns, the adjustment impacted wear area, wear depth, and fracture force (p=0.006), with adjusted zirconia crowns exhibiting more wear and lower maximum forces until fracture.

  • Zirconia wear depth was also impacted by the occlusal design Antagonistic wear was influenced by the restorative material, the occlusal contact pattern, and the adjustment.

The investigated materials show strongly varying performances with zirconia being significantly influenced by the adjustment, while for resin composites, contact design and adjustment had a major impact. The results show the necessity of adapting occlusal design and adjustment in order to improve roughness, wear, and stability of zirconia and resin composite crowns.


Reference:

Karin Schnitzhofer, Angelika Rauch, Micheal Schmidt, Martin Rosentritt,

Impact of the occlusal contact pattern and occlusal adjustment on the wear and stability of crowns, Journal of Dentistry, 2022, 104364, ISSN 0300-5712,

https://doi.org/10.1016/j.jdent.2022.104364


Tags:    
Article Source : Journal of Dentistry

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News