Surface Smoothness of stainless steel orthodontic archwires not affected by Use of salbutamol inhalers in asthma patients: Study

Written By :  Dr. Shravani Dali
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2024-08-16 15:15 GMT   |   Update On 2024-08-17 05:43 GMT
Advertisement

Smoothness of surface of stainless steel orthodontic archwires not affected by Use of salbutamol inhalers among asthma patients suggests a study published in the Clinical Dentistry.

This study aimed to compare the surface roughness and friction of different orthodontic archwires after exposure to salbutamol sulphate inhalation, an anti-asthmatic medication.

Orthodontic archwires (stainless-steel [StSt], nickel-titanium [NiTi], beta-titanium [β-Ti], and copper-NiTi [Cu-NiTi]) were equally divided into two groups. The exposed groups were subjected to 20 mg salbutamol sulphate for 21 days and kept in artificial saliva. The control groups were only kept in artificial saliva. Surface changes were visualized using scanning electron microscopy (SEM). The average surface roughness (Ra) was evaluated using atomic force microscopy (AFM), and friction resistance forces were assessed using a universal testing machine. Statistical analyses were performed using t-tests and ANOVA followed by post hoc tests. Results: Salbutamol sulphate did not change the surface roughness of StSt and NiTi archwires (p > .05).

Advertisement

However, the change in the surfaces of β-Ti and Cu-NiTi archwires was significant (p < .001). The frictional forces of exposed StSt, NiTi, and Cu-NiTi archwires did not change (p > .05). However, the frictional forces of β-Ti archwires increased significantly after exposure to salbutamol sulphate (p = .021). Brushing with fluoride after exposure to salbutamol sulphate increased the frictional forces of β-Ti only (p = .002). Salbutamol sulphate inhalation significantly affected the surface texture of β-Ti and Cu-NiTi orthodontic archwires and increased the friction of β-Ti archwires. These deteriorating effects were not detected on the surface of StSt and NiTi archwires. Therefore, we suggest that β-Ti and copper titanium archwires should be used cautiously in individuals under salbutamol sulphate inhalation treatment.

Reference:

Alemran MA, Abbassy MA, Bakry AS, Alsaggaf DH, Abuhaimed TS, Zawawi KH. The effect of salbutamol sulphate inhalation (an anti-asthmatic medication) on the surfaces of orthodontic Archwires. Orthod Craniofac Res. 2024; 27: 447-454. doi:10.1111/ocr.12749

Tags:    
Article Source : Clinical Dentistry

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News