Arthroscopic debridement bests subacromial balloon spacer for irreversible rotator cuff injury: Lancet

Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2022-06-02 14:30 GMT   |   Update On 2022-06-02 14:30 GMT
Advertisement

UK: For people with irreparable rotator cuff tears, arthroscopic debridement was superior to the same surgery done with the InSpace device, says an article published in The lancet.

New surgical techniques can endanger patients and should be thoroughly evaluated before they are widely used. The InSpace balloon (Stryker, USA) is a novel surgical gadget used to treat people with irreparable rotator cuff tears. As a result, Andrew Metcalfe and his colleagues set out to test the efficacy of the InSpace balloon for individuals with irreparable rotator cuff tears.

Advertisement

This was a group-sequential, double-blind, adaptive randomized controlled trial conducted in 24 UK hospitals, comparing arthroscopic debridement of the subacromial space with biceps tenotomy (debridement only group) to the same procedure but including the insertion of the InSpace balloon (debridement with device group). Participants had an irreversible rotator cuff injury that had not healed with conservative therapy and symptoms that necessitated surgery. Eligibility was confirmed intraoperatively before participants were randomly assigned (1:1) to a treatment group using a remote computer system. The group assignment was kept a secret from both the participants and the assessors. Masking was accomplished by utilizing similar incisions for both treatments, blinding the operation note, and providing a uniform rehabilitation regimen independent of group assignment. The Oxford Shoulder Score at 12 months was the primary outcome.

The key findings were as follows:

1. The researchers screened 385 persons for eligibility between June 1, 2018, and July 30, 2020, and 317 were found to be eligible. 249 participants (79%) agreed to participate in the research.

2. A total of 117 individuals were randomly assigned to a therapy group, with 61 assigned to the debridement-only group and 56 assigned to the debridement plus device group.

3. At the first intermediate analysis, a preset stopping threshold was reached, and recruitment was halted with 117 individuals randomly assigned.

4. 43% of those who took part were female, while 57% were male.

5. The researchers collected main outcome data from 114 (97%) of the participants.

6. At 12 months, the mean Oxford Shoulder Score was 343 in the debridement only group and 303 (109) in the debridement plus device group, favoring control.

7. In terms of adverse occurrences, there was no variation between the groups.

In conclusion, this study's findings favored the debridement-only group. The InSpace balloon is not recommended by researchers for the treatment of irreversible rotator cuff injuries.

Reference:

Metcalfe, A., Parsons, H., Parsons, N., Brown, J., Fox, J., Gemperlé Mannion, E., Haque, A., Hutchinson, C., Kearney, R., Khan, I., Lawrence, T., Mason, J., Stallard, N., Underwood, M., Drew, S., Metcalfe, A., Parsons, H., Parsons, N., Arif, A., … Howard, A. (2022). Subacromial balloon spacer for irreparable rotator cuff tears of the shoulder (START:REACTS): a group-sequential, double-blind, multicentre randomised controlled trial. In The Lancet. Elsevier BV. https://doi.org/10.1016/s0140-6736(22)00652-3

Tags:    
Article Source : The Lancet

Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.

NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News