Ceramic bearings tied to reduced revision rate in Primary Hip Arthroplasty: Study

Written By :  Dr. Nandita Mohan
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2021-06-23 04:30 GMT   |   Update On 2021-06-23 05:11 GMT

Researchers from a recent study have found out that there is an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes. The study is published in the Journal of Arthroplasty. Prosthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings. Hence,...

Login or Register to read the full article

Researchers from a recent study have found out that there is an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes.

The study is published in the Journal of Arthroplasty.

Prosthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings.

Hence, Richard Holleyman and associates from the Newcastle University Institute of Cellular Medicine, Newcastle, UK carried out the present study to assess the association Ceramic bearings and revision rate in Primary Hip Arthroplasty.

Adult patients who underwent total hip arthroplasty (THA) using an uncemented acetabular component with ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP ) or metal-on-polyethylene (MoP) bearing surfaces were extracted from the National Joint Registry for England, Wales, Nortern Ireland and the Isle of Man.

A competing risk regression model to investigate predictors of each revision outcome was used. Time-to-event was determined by duration of implantation since primary surgery with competing risks being death or revision.

The results were adjusted for age, gender, American Association of Anaesthesiologists grade (ASA), Body Mass Index (BMI), surgical indication, intraoperative complications and implant data.

The findings highlighted were as follows-

a. 456,457 THA (228,786 MoP, 128,403 CoC and 99,268 CoP) were identified.

b. Multivariable modelling showed the risk of revision for PJI was significantly lower with CoC (Risk Ratio (RR) 0.748, p<0.001) and CoP (RR 0.775, p<0.001) compared to MoP.

c. Significant reduction in risk of aseptic and all cause revision was also seen.

d. The significant protective effect of ceramic bearing was predominantly seen two years after implantation.

d. Aseptic revision beyond two years reduced by 18.1% and 24.8% for CoC & CoP (p<0.001), respectively.

e. All cause revision rate beyond two years reduced by 21.6% for CoC & 27.1% for CoP (p<0.001).

Therefore, the authors concluded that "there is an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes, revision for infection and revision for aseptic causes, supporting ceramic bearings in THA."

Tags:    
Article Source : Journal of Arthroplasty

Disclaimer: This site is primarily intended for healthcare professionals. Any content/information on this website does not replace the advice of medical and/or health professionals and should not be construed as medical/diagnostic advice/endorsement/treatment or prescription. Use of this site is subject to our terms of use, privacy policy, advertisement policy. © 2024 Minerva Medical Treatment Pvt Ltd

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News