Plate and screws system viable osteosynthesis method for treatment of unstable and comminuted scaphoid fractures: study
For unstable scaphoid fractures failure rates are as high as 92% especially with an initial displacement exceeding one millimeter, which is why surgical treatment became the gold standard.
The primary method employed worldwide for the treatment of scaphoid fractures is screw fixation. However, in unstable and comminuted fractures, percutaneous fixation could produce complications due to technical challenges, such as improper axis positioning, inaccurate screw length measurement, intra-articular screw penetration, and impingement.
Alternative open approaches for the surgical management of scaphoid fractures have been proposed, and in recent years, a new specific volar locking plate for the treatment of scaphoid fractures has been developed.
L. Marzella et al conducted a study to verify the effectiveness of the volar plate in the treatment of comminuted scaphoid fractures and the necessity for plate removal when consolidation has occurred. It has been published in ‘European Journal of Orthopaedic Surgery & Traumatology.’
The authors present results and consideration about a case series of 44 comminuted scaphoid fractures treated with volar locking and angular stability plate. A retrospective study was conducted involving all patients, consisting of continuous clinical and radiographic assessments, functional evaluations (using QuickDASH and MHQ), and patient satisfaction surveys. The Kolmogorov–Smirnov test was used to determine the normal distribution of data. A paired t test was performed to evaluate the difference between the preoperative and postoperative values. A P-value of
Key findings of the study were:
• All fractures had traumatic causes, with the majority resulting from car accidents.
• All patients achieved clinical and radiographic recovery. However, the plate can impinge with nearby structures and should be removed once the fracture is consolidated.
• After plate removal, further improvement in range of motion was observed.
The authors concluded that - “The plate and screws system is a viable and appropriate method of osteosynthesis in the treatment of unstable and comminuted recent fractures occurring in the middle third of the carpal scaphoid.”
Further reading:
Volar locking and angular stability plate for treatment of comminuted scaphoid fractures: a case series of 44 cases.L. Marzella et al European Journal of Orthopaedic Surgery & Traumatology https://doi.org/10.1007/s00590-024-04095-2
Disclaimer: This website is primarily for healthcare professionals. The content here does not replace medical advice and should not be used as medical, diagnostic, endorsement, treatment, or prescription advice. Medical science evolves rapidly, and we strive to keep our information current. If you find any discrepancies, please contact us at corrections@medicaldialogues.in. Read our Correction Policy here. Nothing here should be used as a substitute for medical advice, diagnosis, or treatment. We do not endorse any healthcare advice that contradicts a physician's guidance. Use of this site is subject to our Terms of Use, Privacy Policy, and Advertisement Policy. For more details, read our Full Disclaimer here.
NOTE: Join us in combating medical misinformation. If you encounter a questionable health, medical, or medical education claim, email us at factcheck@medicaldialogues.in for evaluation.