- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
Double Sequential External Defibrillation and VC Defibrillation Increase Survival in Cardiac Arrest Patients: Study

Canada: A recent study published in the Resuscitation Journal highlighted the benefits of alternate defibrillation strategies in reducing the duration of ventricular fibrillation (VF) and improving survival rates.
"Double sequential external defibrillation (DSED) and vector change (VC) defibrillation reduced the duration of VF compared to standard shocks (83 & 98 seconds versus 108 seconds, respectively). DSED demonstrated the highest rates of return of spontaneous circulation (17.6% versus 5.3%) and survival to hospital discharge (10.2% versus 3.5%) compared to standard shocks, indicating their potential to improve cardiac arrest outcomes," the researchers reported.
Double sequential external defibrillation, a technique that delivers two defibrillation shocks in quick succession from separate devices, demonstrated the most promising results. Survival following out-of-hospital cardiac arrest (OHCA) is closely linked to the duration of ventricular fibrillation. However, the effect of vector change defibrillation and DSED on VF duration has not been investigated thoroughly. Considering this, Sheldon Cheskes, Institute of Medical Sciences, University of Toronto, Toronto, Ontario, Canada, and colleagues aimed to evaluate the impact of VC and DSED on VF duration and defibrillation effectiveness.
For this purpose, the researchers conducted a secondary analysis of patients enrolled in the Double Sequential External Defibrillation for Refractory VF RCT. They evaluated ECG recordings following each shock, measuring VF duration (median, IQR) and assessing shock outcomes. To compare VF duration among different groups, the Kruskal-Wallis test was applied, followed by post-hoc pairwise comparisons using Dunn’s test with Bonferroni correction. Shock outcomes were analyzed using chi-square tests.
The study revealed the following findings:
- One thousand eight hundred forty-two shocks were analyzed among 342 patients, including 834 shocks following three failed standard shocks (429 standard, 218 VC, 187 DSED).
- Median VF duration was significantly shorter with DSED (83 [0, 120] s) and VC (98 [0, 120] s) compared to standard shocks (108 [38, 120] s).
- The rate of ROSC was higher for DSED (17.6%) and VC (14.2%) compared to standard shocks (5.3%).
- Survival to hospital discharge was greater for DSED (10.2%) and VC (7.3%) than for standard shocks (3.5%).
- The proportion of shocks in which VF was not terminated was significantly lower for DSED (29.9%) than standard shocks (40.6%).
"In the DOSE VF RCT, patients who received DSED and VC shocks experienced a shorter VF duration than those given standard shocks. Both DSED and VC shocks were significantly more effective in achieving ROSC and improving survival to hospital discharge," the researchers wrote.
"The reduced VF duration observed with these alternative defibrillation strategies may help explain the survival benefits seen in the trial," they concluded.
Reference:
Cheskes, S., Drennan, I. R., Turner, L., Pandit, S. V., Walker, R. G., & Dorian, P. (2025). The impact of alternate defibrillation strategies on time in ventricular fibrillation. Resuscitation, 110549. https://doi.org/10.1016/j.resuscitation.2025.110549
MSc. Biotechnology
Medha Baranwal joined Medical Dialogues as an Editor in 2018 for Speciality Medical Dialogues. She covers several medical specialties including Cardiac Sciences, Dentistry, Diabetes and Endo, Diagnostics, ENT, Gastroenterology, Neurosciences, and Radiology. She has completed her Bachelors in Biomedical Sciences from DU and then pursued Masters in Biotechnology from Amity University. She has a working experience of 5 years in the field of medical research writing, scientific writing, content writing, and content management. She can be contacted at  editorial@medicaldialogues.in. Contact no. 011-43720751
Dr Kamal Kant Kohli-MBBS, DTCD- a chest specialist with more than 30 years of practice and a flair for writing clinical articles, Dr Kamal Kant Kohli joined Medical Dialogues as a Chief Editor of Medical News. Besides writing articles, as an editor, he proofreads and verifies all the medical content published on Medical Dialogues including those coming from journals, studies,medical conferences,guidelines etc. Email: drkohli@medicaldialogues.in. Contact no. 011-43720751