- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
Early detection of cardiac implantable electronic device-related infections reduces mortality: JAMA
Canada: An original investigation published in JAMA Cardiology, entitled "Association of the Timing and Extent of Cardiac Implantable Electronic Device Infections With Mortality”, has concluded detecting and treating Cardiac implantable electronic device (CIED) infection early significantly reduced the rate of mortality associated with this complication.
CIED infection is a potentially devastating complication. The estimated 12-month mortality associated with this complication is 15% to 30%. The question is, “What is the association of the extent and timing of infection with all-cause mortality?”. This is because the data in this context is limited.
Investigating further the aforementioned background, researchers did a cohort study including 19 559 patients of mean age 68.7 years, 74.6 % male, undergoing cardiac implantable electronic device procedures in 28 centres across Canada and the Netherlands.
The study results could be summarised as follows:
- One hundred seventy-seven patients developed CIED infection.
- Within 3, 6, and 12 months, the cumulative incidence of infection was 0.6%, 0.7%, and 0.9% respectively.
- The infection rate was highest in the first three months, at 0.21% per month and reduced significantly afterwards.
- Those with early localized infections were not at higher risk for all-cause mortality compared with patients who did not develop CIED infection, with an adjusted hazard ratio of 0.64.
- Those with early systemic and delayed localized infections had a 3-fold increase in mortality (8.9% 30-day mortality with aHR, 2.88 and 8.8% 30-day mortality with aHR 3.57 increasing to a 9.3-fold risk of death for those with delayed systemic infections, (21.7% 30-day mortality and aHR of 9.30).
We evaluated the association of the extent and timing of CIED infection with all-cause mortality. We reported that those with early localized infections were not at higher risk of all-cause mortality.
Concluding, those with early systemic infections and delayed localized infections had higher mortality, with the highest risk for patients with delayed systemic infections.
The study has addressed the importance of early detection and treatment of CIED infections in reducing mortality associated with this complication.
Further reading:
Han H, Wang J, Birnie DH, et al. Association of the Timing and Extent of Cardiac Implantable Electronic Device Infections With Mortality. JAMA Cardiol. Published online April 05, 2023. doi:10.1001/jamacardio.2023.0467
early detection and treatment of cardiac implantable electronic device–related infections may be important in reducing associated mortality.
BDS, MDS in Periodontics and Implantology
Dr. Aditi Yadav is a BDS, MDS in Periodontics and Implantology. She has a clinical experience of 5 years as a laser dental surgeon. She also has a Diploma in clinical research and pharmacovigilance and is a Certified data scientist. She is currently working as a content developer in e-health services. Dr. Yadav has a keen interest in Medical Journalism and is actively involved in Medical Research writing.
Dr Kamal Kant Kohli-MBBS, DTCD- a chest specialist with more than 30 years of practice and a flair for writing clinical articles, Dr Kamal Kant Kohli joined Medical Dialogues as a Chief Editor of Medical News. Besides writing articles, as an editor, he proofreads and verifies all the medical content published on Medical Dialogues including those coming from journals, studies,medical conferences,guidelines etc. Email: drkohli@medicaldialogues.in. Contact no. 011-43720751