- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
Novel mapping-integrated Pulsed-field ablation system effective against refractory paroxysmal AF
In the single-arm inspIRE study conducted by Mattias Duytschaever and team, a novel pulsed-field ablation system using the Varipulse catheter and the Trupulse generator (Biosense Webster) appeared to effectively treat patients with drug-refractory paroxysmal atrial fibrillation (AF). The findings of this study were published in the Circulation: Arrhythmia and Electrophysiology.
The PFA system was used to perform pulmonary vein isolation (PVI) on the research participants, using at least 12 applications per vein. Adenosine/isoproterenol was also given to ensure that the entry block had been achieved. Wave I evaluated early safety, taking into account PV stenosis, silent cerebral lesions (SCLs), and esophageal lesions. Wave II (pivotal phase) examined the primary efficacy of the verified PVI with independence from recorded atrial arrhythmia at 12 months, as well as the primary safety of the incidence of early onset primary adverse events (PAEs) (12M). When 30 patients completed 12M follow-up (FU) and all subjects reached 3M FU, the study's design called for an interim analysis to identify early success.
The key findings of this study were:
226 participants were enrolled across 13 facilities in Europe and Canada, completed the requirements for safety and efficacy assessments, and were given PFA.
Wave I didn't show any PV stenosis or heat lesions in the esophagus.
With the implementation of process improvements, such as a 10-second delay between PFA applications, only 4 of the 39 participants with cerebral MRI who initially showed SCLs were found to have them.
There were no PAE reports during the Wave II phase. Early success was declared when 83 patients attained 12M FU.
PVI without acute reconnection was accomplished in 97.1% of the targeted veins with 100% entry block.
At the time of interim analysis, the primary efficacy goal for Wave II was 70.9% according to Kaplan Meier; 12M independence from symptomatic AF/atrial flutter/atrial tachycardia recurrent and repeat ablation were both 78.9% and 92.3%.
The durations of the whole operation and the actual PFA were 70.1 ± 27.7 min and 26.7 ± 14.0 min, respectively.
Reference:
Duytschaever, M., De Potter, T., Grimaldi, M., Anic, A., Vijgen, J., Neuzil, P., Van Herendael, H., Verma, A., Skanes, A., Scherr, D., Pürerfellner, H., Rackauskas, G., Jaïs, P., & Reddy, V. Y. (2023). Paroxysmal AF Ablation Using a Novel Variable-Loop Biphasic Pulsed Field Ablation Catheter Integrated With a 3D Mapping System: 1-Year Outcomes of the Multicenter inspIRE Study. In Circulation: Arrhythmia and Electrophysiology. Ovid Technologies (Wolters Kluwer Health). https://doi.org/10.1161/circep.122.011780
Neuroscience Masters graduate
Jacinthlyn Sylvia, a Neuroscience Master's graduate from Chennai has worked extensively in deciphering the neurobiology of cognition and motor control in aging. She also has spread-out exposure to Neurosurgery from her Bachelor’s. She is currently involved in active Neuro-Oncology research. She is an upcoming neuroscientist with a fiery passion for writing. Her news cover at Medical Dialogues feature recent discoveries and updates from the healthcare and biomedical research fields. She can be reached at editorial@medicaldialogues.in
Dr Kamal Kant Kohli-MBBS, DTCD- a chest specialist with more than 30 years of practice and a flair for writing clinical articles, Dr Kamal Kant Kohli joined Medical Dialogues as a Chief Editor of Medical News. Besides writing articles, as an editor, he proofreads and verifies all the medical content published on Medical Dialogues including those coming from journals, studies,medical conferences,guidelines etc. Email: drkohli@medicaldialogues.in. Contact no. 011-43720751