- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
Methacrylate Threadlockers found best for Enhancing Abutment Screw Retention: Study

Researchers have found in a new study that threadlockers significantly improved abutment screw retention, with methacrylate outperforming dimethacrylate. Reduced detorque under cyclic loading emphasizes the need for improved retention strategies, and methacrylate-based threadlockers may help prevent screw loosening and improve long-term implant success.
A study was done to evaluate and compare the effects of different thread lockers on implant abutment screw loosening. Thirty implant-abutment assemblies were divided into 3 groups: Control group (without threadlocker), dimethacrylate group, and methacrylate group. Each group was subdivided into static and dynamic groups. The specimens were torqued to 35 Ncm, and detorque values were measured after 1 month in static conditions and after cyclic loading. The cyclic loading protocol involved 240,000 cycles at a velocity of 16 mm/s over a 48-h period in a moist environment, simulating 1 year of clinical function.
Results were assessed using one-way, two-way ANOVA and multiple pairwise comparisons with a significance level of P ≤ 0.05. The methacrylate group demonstrated the highest detorque values (static: 36.46 ± 0.95 Ncm, dynamic: 33.22 ± 0.34 Ncm), followed by the dimethacrylate group (static: 32.84 ± 1.12 Ncm, dynamic: 29.98 ± 1.05 Ncm). The control group exhibited the lowest detorque values (static: 28.80 ± 0.96 Ncm, dynamic: 25.84 ± 0.63 Ncm). Detorque values were consistently higher in the static condition (32.40 ± 3.37 Ncm) compared to the dynamic condition across all groups (29.68 ± 3.20 Ncm), with statistically significant differences observed (P = 0.000).
Within the limitations of the study, application of threadlockers significantly improved abutment screw retention, with methacrylate exhibiting superior performance over dimethacrylate. The reduction in detorque values under cyclic loading highlights the need for enhanced retention strategies in implant prosthetics. Incorporating methacrylate-based threadlockers in clinical practice may mitigate screw loosening and enhance the long-term success of implant-supported prostheses.
Reference:
Arul, Lizy Teena, et al. "Comparative Evaluation of Abutment Screw Loosening With Two Different Thread Lockers Under Cyclic Loading: an in Vitro Study." Journal of Indian Prosthodontic Society, vol. 26, no. 1, 2026, pp. 49-55.
Dr. Shravani Dali has completed her BDS from Pravara institute of medical sciences, loni. Following which she extensively worked in the healthcare sector for 2+ years. She has been actively involved in writing blogs in field of health and wellness. Currently she is pursuing her Masters of public health-health administration from Tata institute of social sciences. She can be contacted at editorial@medicaldialogues.in.
Dr Kamal Kant Kohli-MBBS, DTCD- a chest specialist with more than 30 years of practice and a flair for writing clinical articles, Dr Kamal Kant Kohli joined Medical Dialogues as a Chief Editor of Medical News. Besides writing articles, as an editor, he proofreads and verifies all the medical content published on Medical Dialogues including those coming from journals, studies,medical conferences,guidelines etc. Email: drkohli@medicaldialogues.in. Contact no. 011-43720751

