- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
Reprocessing, reuse of single-use medical devices: Medical Bodies submit recommendations to DGHS

New Delhi: Medical associations including the Association of Healthcare Providers of India (AHPI), Association of National Board Accredited Institutions (ANBAI), the Consortium of Accredited Healthcare Organisations (CAHO), and Health and Environment Leadership Platform (HELP) have submitted recommendations to the Director General of Health Services (DGHS) on the reprocessing and reuse of single-use medical devices.
This exercise was undertaken with inputs from several professional associations and hospitals, many of which participated in the two committees constituted for this purpose.
One of these two committees, comprising Dr. Lallu Joseph (President, CAHO), Dr. Harvinder Chhabra (President, ANBAI), Dr. Charudatta (Advisor, AHPI), and Dr. Alexander Thomas (AHPI, CAHO, ANBAI and HELP), classified 281 medical devices into five (5) categories to ascertain whether they can be considered for reprocessing or not. Technical experts who undertook the preparation, review, and finalisation of the document included Dr. Sangeetha (Manipal Hospitals), Dr. Uthappa P.M and the Quality team (Narayana Health), and Dr. Rajalakshmi (KIMS Health, Thiruvananthapuram)
The baseline document was circulated to approximately 30 medical speciality associations and 15 hospitals to obtain expert feedback and recommendations. After examining the feedback received, the committee incorporated appropriate feedback and subsequently undertook a further review and finalisation of the document, with the assistance of the technical experts.
Meanwhile, another committee, led by Dr. Girdhar J. Gyani and Dr. Sanjeev Singh, has outlined the framework for safe, affordable and accountable practice of regulated reprocessing of single-use medical devices in India.
It includes purpose and policy decisions, working definitions, scope, and device eligibility. Further, it discusses what the evidence shows regarding different types of medical devices, technical validation standards, minimum operating protocol for hospital reprocessing, legal, regulatory and surveillance architecture, and patient rights, disclosure, and ethics.
Classification of Single-Use Medical Devices:
The first committee has classified 281 medical devices into five (5) categories to ascertain whether they can be considered for reprocessing or not. These five categories are as follows:
(1) R1: Low risk / simple design – simple devices with accessible surfaces, minimal complexity and demonstrable cleanability. May be considered for reprocessing under appropriate protocols.
(2) R2: Moderate risk – devices requiring more stringent cleaning, disinfection/sterilisation and functional assessment. Reprocessing only under validated and controlled conditions.
(3) R3: High Risk/complex – devices with lumens, complex mechanisms, sensitive materials or high functional risk. Device-specific validation, specialty review and regulatory assessment required.
(4) SPU: Single-patient use – may be used more than once on the same patient, with cleaning between uses as per IFU; never used on another patient.
(5) NR: Not recommended – devices with unacceptable infection, contamination, material, functional, or design risks. Not recommended for reuse.
Regulated Reprocessing of Single-Use Medical Devices in India: A Framework for Safe, Affordable and Accountable Practice:
The second committee has prepared the framework for Safe, Affordable and Accountable Practice of reprocessing of Single-Use Medical Devices in India.
The document underlines that because of high acquisition costs, devices labelled by manufacturers for "single use" (single-use medical devices, SUMDs) have been reused in Indian clinical practice for decades. However, under the DGHS order dated 16.10.2026, this reuse is inconsistent with the Medical Devices Rules (MDR), 2017.
It has been observed by the committee that neither unregulated reuse nor a blanket prohibition serves patients, and India should expressly permit the reprocessing and reuse of selected SUMDs through a transparent, CDSCO-administered approval pathway, in which applicants prove that a given device and process meet defined requirements, and regulators apply proportionate evidence standards, take transparent decisions and maintain continuing oversight.
Recommendations:
The committee has recommended the Government to-
(1) Adopt regulated reprocessing as national policy and give it legal effect by amending MDR 2017 or notifying guidance under the Drugs and Cosmetics Act, after legal vetting.
(2) Notify the two registration routes for commercial reprocessors and hospital CSSDs, with liability and insurance obligations.
(3) Notify the risk-based eligibility framework and the Negative List.
(4) Constitute CDSCO expert technical committees to set device-group acceptance limits and Common Specifications for hospital CSSDs.
(5) Clarify the scope of the DGHS order for devices reused in line with manufacturer instructions (multiple-use dialysers, reusable or single-patient-use accessories) and for ophthalmic consumables.
(6) Handle dialyser reuse as a separate track aligned with ISN guidance and the national dialysis programme, preceded by a continuity-of-care assessment.
(7) Authorise regulator-supervised pilots for high-cost categories with limited evidence, beginning with OPCAB tissue stabilisers.
(8) Set minimum CSSD equipment and training standards and enable licensed shared reprocessing facilities for district and rural hospitals.
(9) Mandate reporting to the Materiovigilance Programme and establish a central register of authorised device–process combinations.
(10) Codify patient disclosure, fair billing and opt-out protections, including continued scheme eligibility.
Speaking to Medical Dialogues, Dr. Alexander Thomas said, "It is a very positive thing that the government asked for our recommendations. We have submitted the suggestions and now the government will finalise the policy and the list."
M.A in English Barsha completed her Master's in English from the University of Burdwan, West Bengal in 2018. Having a knack for Journalism she joined Medical Dialogues back in 2020. She mainly covers news about medico legal cases, NMC/DCI updates, medical education issues including the latest updates about medical and dental colleges in India. She can be contacted at editorial@medicaldialogues.in.