- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
Safety Concerns Raised Over Some Repeated Low-Level Red Light Therapy Devices for Myopia Control: JAMA

A new study published in the Journal of American Medical Association showed that the safety profile of recurrent low-level red light (RLRL) treatment devices used to manage myopia varies. Two devices (Eyerising and Sky-n1201a) exceeded set safety limits for lasers and ophthalmic light exposure, according to investigators.
Red laser therapy, or repetitive low-level red light, has become a popular treatment for myopia in Asia and is being considered more and more internationally. However, there hasn't been a thorough assessment of the ocular safety of commercially marketed devices. Therefore, following American National Standards Institute (ANSI) requirements, this study was carried out to evaluate the optical output and safety categorization of four commercially available red light therapy devices for the management of myopia.
From November 25, 2023, to April 30, 2024, a laboratory-based assessment of the Sky-n1201, Future Vision, EyeRising, and AirDoc devices was conducted as part of this quality improvement project. Radiometric power was measured using an integrating sphere radiometer at 1- and 10-cm distances through a 7-mm aperture and retinal irradiance computed for 2- to 7-mm pupil diameters. Safety categorization was evaluated according to ANSI Z80.36-2021 and ANSI Z136.1-2022 standards. The period of data analysis was November 25, 2023, through September 10, 2024. The key conclusion was analyzing the time to the group 1 safety limit and the ANSI device classification. This was assessed by laboratory-based examination of 4 devices and evaluating radiometric power at various pupil diameters.
The Sky-n1201 and EyeRising devices met ANSI group 1 restrictions within exposure durations of 2.8 and 1.4 seconds, respectively, for a 7-mm pupil and are categorized as Class 1 and 2M laser devices, respectively. The Future Vision gadget surpassed group 1 limitations with lengthy exposure durations of 253 seconds or more but stayed inside restrictions for Class 1 laser categorization. With a time to group 1 limit of 22,761 seconds, the light-emitting diode-based AirDoc provided diffuse lighting and was categorized as group 1.
Overall, these results imply that during exposure intervals less than the suggested 180-second treatment duration, laser-based red light therapy devices provide irradiance levels that meet ANSI safety requirements. These results, together with new clinical reports of retinal injury and China's recent regulatory categorization of red laser devices as Class III, underscore the necessity of thorough, independent safety validation prior to broad pediatric usage.
Reference:
Ostrin, L. A., & Schill, A. W. (2026). Safety evaluation of 4 red light therapy devices for myopia. JAMA Ophthalmology, 144(3), 255–258. https://doi.org/10.1001/jamaophthalmol.2025.5660
Neuroscience Masters graduate
Jacinthlyn Sylvia, a Neuroscience Master's graduate from Chennai has worked extensively in deciphering the neurobiology of cognition and motor control in aging. She also has spread-out exposure to Neurosurgery from her Bachelor’s. She is currently involved in active Neuro-Oncology research. She is an upcoming neuroscientist with a fiery passion for writing. Her news cover at Medical Dialogues feature recent discoveries and updates from the healthcare and biomedical research fields. She can be reached at editorial@medicaldialogues.in
Dr Kamal Kant Kohli-MBBS, DTCD- a chest specialist with more than 30 years of practice and a flair for writing clinical articles, Dr Kamal Kant Kohli joined Medical Dialogues as a Chief Editor of Medical News. Besides writing articles, as an editor, he proofreads and verifies all the medical content published on Medical Dialogues including those coming from journals, studies,medical conferences,guidelines etc. Email: drkohli@medicaldialogues.in. Contact no. 011-43720751