- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
New optical biosensor system may help Gout patients monitor their symptoms better
The researchers at Texas A&M University have explored the fabrication and characterization of an optical, enzymatic urate biosensor for gout management, and the optimization of the biosensor response through the tuning of hydrogel matrix properties. The technology that might help people with gout disease monitor their symptoms better. They said their minimally invasive biosensor system may hold the key to future point-of-care therapies centered around personal management of gout, and possibly other conditions.
The research has been published in the journal Sensors.
"Finding more ways to help patients reduce their risks of gout attacks is an important clinical need that hasn't been looked at in detail," said Dr. Mike McShane, department head and professor in the Department of Biomedical Engineering. "In the future, biosensor technology such as ours can potentially help patients take preemptive steps to reduce the severity of their symptoms and lower their long-term health costs from repeated lab visits."
Gout is a painful joint disease that affects over 8 million Americans. Patients with gout tend to have higher levels of urate salts circulating in their bloodstream, a condition called hyperuricemia. These urate crystals then diffuse out of blood vessels and accumulate in the space between joints. The salt deposits then cause excruciating pain, and in advanced cases, a deterioration of joints and bones.
For gout diagnosis, physicians often use clinical criteria, like the frequency of painful incidents, location of pain and the severity of the inflammation. But for a definitive diagnosis, the fluid between the joints is examined for the presence and quantity of urate crystals. These laboratory tests can be expensive and time-consuming due to factors such as equipment and labor costs. Also, the researchers said frequent visits for laboratory testing can be difficult for elderly gout patients.
However, levels of circulating urate can be kept in check with medications. Additionally, avoiding or minimizing the consumption of foods rich in urates, like red meat and seafood, can also help in managing blood urate levels.
"Maintaining low levels of urate is critical for mitigating gout symptoms," said Tokunbo Falohun, a graduate student in the College of Engineering and the primary author of the study. "And so, we wanted to create a technology that is reliable and user-friendly so that patients can easily self-monitor their blood urate levels."
Urate reacts with oxygen in the presence of an enzyme called uricase to form allantoin. The researchers used this knowledge to develop a system where urate levels could be indirectly monitored using benzoporphyrins, a known sensor for oxygen.
Benzoporphyrins are complex molecules that have unique optical properties that are valuable in the design of optical biosensors. When hit by light from an LED, benzoporphyrins get energized, and after a short time, lose their excess in stages and finally emit light. But oxygen atoms can affect the amount of time or lifetimes of benzoporphyrins in an energized state.
Through collisions, oxygen atoms can take away some of the excess energy from the benzoporphyrins. And so, if there are fewer oxygen atoms, there are lesser that bump into benzoporphyrins and the lifetimes of benzoporphyrins proportionately increase. The researchers reasoned that when urate levels are high, benzoporphyrins lifetimes must be higher since more oxygen is used up to make allantoin.
Based on this rationale, McShane and Falohun set up a technology to measure benzoporphyrins' lifetimes. Their technology consisted of two main components: an optical device to both produce light and collect emitted light from benzoporphyrins; and a biocompatible hydrogel platform for encapsulating uricase and benzoporphyrins.
To mimic conditions within the body, the researchers put the pieces of hydrogels, which were thin discs millimeters in diameter, in saline-filled chambers receiving a steady flow of oxygen and continually maintained at 37 degrees Celsius. In each chamber, they then put in different levels of urate. An external computer connected to the optical system calculated and reported the lifetimes of the benzoporphyrins.
The researchers found that when they switched on the LED light, as predicted, the urate levels in each chamber directly affected the lifetimes of the benzoporphyrins. That is if there was more urate, there were fewer oxygen atoms available for collisions and consequently, the lifetimes of the benzoporphyrins were higher.
Although the lifetime values faithfully followed urate levels, McShane and Falohun said that additional experiments need to be done to ensure long-term stability of their optical biosensor system so that the technology is suitable for future clinical use.
However, they noted that their biosensor system demonstrates the feasibility of using the technology for personal management of gout since the hydrogels are small enough to be inserted just below the skin, at a site near oxygen-carrying blood vessels. Furthermore, they said the optical system can be easily connected to any standard computer and that their software is designed to report urate levels in a user-friendly manner. Thus, gout patients will be able to measure their urate levels precisely and as often as they need to.
"From a global health perspective, we need to empower people to make informed decisions about their health and well-being. In that regard, our system is a step toward building biomedical technologies for continuous and more frequent monitoring of disease symptoms," said McShane.
For more details click on the link: http://dx.doi.org/10.3390/s20040959
Hina Zahid Joined Medical Dialogue in 2017 with a passion to work as a Reporter. She coordinates with various national and international journals and association and covers all the stories related to Medical guidelines, Medical Journals, rare medical surgeries as well as all the updates in the medical field. Email:Â editorial@medicaldialogues.in. Contact no. 011-43720751
Dr Kamal Kant Kohli-MBBS, DTCD- a chest specialist with more than 30 years of practice and a flair for writing clinical articles, Dr Kamal Kant Kohli joined Medical Dialogues as a Chief Editor of Medical News. Besides writing articles, as an editor, he proofreads and verifies all the medical content published on Medical Dialogues including those coming from journals, studies,medical conferences,guidelines etc. Email: drkohli@medicaldialogues.in. Contact no. 011-43720751