- Home
- Medical news & Guidelines
- Anesthesiology
- Cardiology and CTVS
- Critical Care
- Dentistry
- Dermatology
- Diabetes and Endocrinology
- ENT
- Gastroenterology
- Medicine
- Nephrology
- Neurology
- Obstretics-Gynaecology
- Oncology
- Ophthalmology
- Orthopaedics
- Pediatrics-Neonatology
- Psychiatry
- Pulmonology
- Radiology
- Surgery
- Urology
- Laboratory Medicine
- Diet
- Nursing
- Paramedical
- Physiotherapy
- Health news
- Fact Check
- Bone Health Fact Check
- Brain Health Fact Check
- Cancer Related Fact Check
- Child Care Fact Check
- Dental and oral health fact check
- Diabetes and metabolic health fact check
- Diet and Nutrition Fact Check
- Eye and ENT Care Fact Check
- Fitness fact check
- Gut health fact check
- Heart health fact check
- Kidney health fact check
- Medical education fact check
- Men's health fact check
- Respiratory fact check
- Skin and hair care fact check
- Vaccine and Immunization fact check
- Women's health fact check
- AYUSH
- State News
- Andaman and Nicobar Islands
- Andhra Pradesh
- Arunachal Pradesh
- Assam
- Bihar
- Chandigarh
- Chattisgarh
- Dadra and Nagar Haveli
- Daman and Diu
- Delhi
- Goa
- Gujarat
- Haryana
- Himachal Pradesh
- Jammu & Kashmir
- Jharkhand
- Karnataka
- Kerala
- Ladakh
- Lakshadweep
- Madhya Pradesh
- Maharashtra
- Manipur
- Meghalaya
- Mizoram
- Nagaland
- Odisha
- Puducherry
- Punjab
- Rajasthan
- Sikkim
- Tamil Nadu
- Telangana
- Tripura
- Uttar Pradesh
- Uttrakhand
- West Bengal
- Medical Education
- Industry
Robot-assisted retrograde elastic intramedullary nailing safe and minimally invasive treatment for displaced midshaft clavicular fractures: study

Yufu Zhang et al conducted a study to compare the clinical outcomes of robot-assisted retrograde elastic intramedullary nailing and open reduction and internal fixation (ORIF) with a plate for displaced midshaft clavicular fractures. It was conducted at Beijing Jishuitan Hospital, Capital Medical University, Beijing, People’s Republic of China. The article has been published in “JBJS open access.”
All patients diagnosed with displaced midshaft clavicular fractures were enrolled in this retrospective study; a total of 116 patients met the inclusion criteria. Patients were divided into 2 groups on the basis of treatment: robot-assisted retrograde elastic intramedullary nailing (RAN group) and ORIF with a plate (plate group). Operations in the RAN group were carried out using the novel TIANJI Robot system (TINAVI Medical Technologies) for navigation and planning of the optimal retrograde intramedullary nailing trajectory. Patient demographics, perioperative parameters, and complications were documented. Patients were followed at the trauma clinic for clinical and radiographic assessment.
The key findings of the study were:
• There were 74 patients in the RAN group and 42 patients in the plate group.
• The RAN group exhibited a significantly shorter total operative time (mean, 52.20 ± 20.76 versus 86.83 ± 27.42 minutes), less blood loss (mean, 7.38 ± 5.54 versus 59.05 ± 30.11 mL), shorter incision length (mean, 1.28 ± 0.85 versus 9.79 ± 1.63 cm), and shorter duration of hospital stay (mean, 3.38 ± 0.73 versus 5.50 ± 1.99 days) (all p < 0.05).
• Nail treatment was also associated with a significantly shorter time to bone union (mean, 7.92 ± 2.46 versus 16.79 ± 5.18 weeks), a higher SCAR score (mean, 9.77 ± 0.51 versus 5.74 ± 1.15), a shorter time to return to sports (mean, 12.70 ± 2.35 versus 20.10 ± 4.10 weeks), and a shorter time to regain full range of shoulder motion (mean, 9.46 ± 2.35 versus 12.05 ± 2.95 weeks) (all p < 0.05).
• At the final follow-up, the Constant-Murley shoulder score was significantly higher in the RAN group (mean, 97.57 ± 2.77 versus 93.29 ± 7.63) (p < 0.05).
• Compared with the RAN group, the plate group had more complications (p < 0.05).
The authors concluded – “Robot-assisted retrograde elastic intramedullary nailing is a safe and minimally invasive treatment option for displaced midshaft clavicular fractures that promotes rapid healing, good cosmesis, excellent functional outcomes, and fewer complications compared with ORIF with a plate.”
Level of Evidence: Therapeutic Level III.
Further reading:
Robot-Assisted Retrograde Elastic Intramedullary Nailing Versus ORIF with a Plate for Displaced Midshaft Clavicular Fractures
Yufu Zhang et al
JBJS Open Access 2025:e24.00071
http://dx.doi.org/10.2106/JBJS.OA.24.00071
MBBS, Dip. Ortho, DNB ortho, MNAMS
Dr Supreeth D R (MBBS, Dip. Ortho, DNB ortho, MNAMS) is a practicing orthopedician with interest in medical research and publishing articles. He completed MBBS from mysore medical college, dip ortho from Trivandrum medical college and sec. DNB from Manipal Hospital, Bengaluru. He has expirence of 7years in the field of orthopedics. He has presented scientific papers & posters in various state, national and international conferences. His interest in writing articles lead the way to join medical dialogues. He can be contacted at editorial@medicaldialogues.in.