Cerebral Protection System reduces rates of CV events and mortality after TAVR

Written By :  MD Bureau
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2022-03-21 03:30 GMT   |   Update On 2022-03-22 03:45 GMT

Almost 4% of individuals over 70 and more than 9% over 80 years of age suffer from severe aortic stenosis (AS). Transcatheter aortic valve replacement (TAVR) has revolutionized treatment options in this common disease, especially in patients with high surgical risk. Despite ongoing improvements in the TAVR procedure, a significant risk of stroke remains. In a recent study, researchers...

Login or Register to read the full article

Almost 4% of individuals over 70 and more than 9% over 80 years of age suffer from severe aortic stenosis (AS). Transcatheter aortic valve replacement (TAVR) has revolutionized treatment options in this common disease, especially in patients with high surgical risk. Despite ongoing improvements in the TAVR procedure, a significant risk of stroke remains. In a recent study, researchers reported that using Sentinel™ device significantly improves clinical outcomes in TAVR patients. The study findings were published in the Journal of Personalized Medicine on February 03, 2022.

Until recently, the Sentinel™ Cerebral Protection System (CPS; Boston Scientific, Marlborough, MA, USA) has been the only commercially available device for mechanical prevention of TAVR-related stroke. However, its effectiveness is still undetermined. Therefore, Dr Julia Mascherbauer and her team conducted a study to explore the impact of Sentinel™ on stroke rate, length of hospital stay (LOS), and twelve-month mortality.

In a single-centre, real-world all-comer intention-to-treat study, the researchers included 411 patients assigned to TAVR with or without Sentinel™. Of 411 patients (80 ± 7 y/o, EuroSCORE II 6.3 ± 5.9%), Sentinel™ was used in 213 (51.8%), with both filters correctly deployed in 189 (46.0%). They determined the primary endpoint as clinically detectable cerebrovascular events within 72 h after TAVR. Secondary endpoints assessed were LOS and 12-month mortality. They used logistic and linear regression analyses to assess associations of Sentinel™ use with endpoints.

Key findings of the study:

  • The researchers observed twenty (4.9%) cerebrovascular events, ten (2.4%) of which were disabling strokes.
  • They found that the patients with Sentinel™ suffered 71% less (univariate analysis; OR 0.29) and 76% less (multivariate analysis; OR 0.24) cerebrovascular events compared to patients without Sentinel™.
  • They also found that Sentinel™ use was also significantly associated with shorter LOS (Regression coefficient −2.47) and lower 12-month all-cause mortality (OR 0.45).

The authors concluded, "In the present prospective all-comers TAVR cohort, patients with systematic use of Sentinel™ showed (1) reduced rates of cerebrovascular events, (2) shortened length of hospital stay (LOS) after TAVR, and (3) a reduction of all-cause mortality at 12 months. These data promote the use of a CPS when implanting TAVR valves. Long-term cost-effectiveness and the impact of anatomical constraints, necessitating customized procedural approaches, require further study."

Keywords: Sentinel™ Cerebral Protection System, transcatheter aortic valve replacement, TAVR, TAVR-related stroke, length of hospital stay, stroke rate, mortality rate, Journal of Personalized Medicine.


Tags:    
Article Source :  Journal of Personalized Medicine

Disclaimer: This site is primarily intended for healthcare professionals. Any content/information on this website does not replace the advice of medical and/or health professionals and should not be construed as medical/diagnostic advice/endorsement/treatment or prescription. Use of this site is subject to our terms of use, privacy policy, advertisement policy. © 2024 Minerva Medical Treatment Pvt Ltd