TMT has limited sensitivity to detect Coronary microvascular disease, finds study

Written By :  Dr Sravan Kumar
Medically Reviewed By :  Dr. Kamal Kant Kohli
Published On 2021-10-15 05:45 GMT   |   Update On 2021-10-15 06:32 GMT

Coronary microvascular disease (CMD) is associated with increased morbidity and mortality even in the absence of flow-limiting epicardial disease. Coronary microvascular disease (CMD) is assessed by direct interrogation (invasive or noninvasive) of coronary microvascular function. Cardiac positron emission tomography (PET) is the non invasive approach for the evaluation of CMD. However, role of TMT in CMD is less studied.

Diana M. Lopez et.al, conducted this study to evaluate sensitivity and specificity of TMT in the diagnosis of CMD. This is a retrospective study done in patients who underwent TMT and PET at Boston, USA. A total of 249 patients were included. Among these 35% tested positive for TMT, 42% were negative and 23% were inconclusive. CFR was reduced (<2) in 98 (39.4%) patients and preserved in 151 (60.6%) patients.

Advertisement

Patients were followed for the occurrence of a first major adverse event, defined as a composite of death or hospitalization for nonfatal MI or heart failure.

Key findings of the study are

1) The sensitivity and specificity of a positive TMT to detect CMD were 34.7% and 64.9% respectively.

2) The specificity of a positive TMT to detect CMD increased to 86.8% when only classifying studies with ischemic electrocardiogram changes that lasted at least 1 minute into recovery as positive, although at a cost of lower sensitivity

3) Over a median follow-up of 6.9 years, 30patients met the composite endpoint, including 13 with CMD. In patients with CMD, TMT result was not associated with the composite endpoint.

Authors concluded that TMT has limited sensitivity to detect CMD. However, a positive TMT with ischemic changes that persist at least 1 minute into recovery in the absence of obstructive CAD should raise suspicion for the presence of CMD given a high specificity.

Source: JACC Cardiovasc Imaging.

Tags:    
Article Source : JACC:cadiovascular imaging

Disclaimer: This site is primarily intended for healthcare professionals. Any content/information on this website does not replace the advice of medical and/or health professionals and should not be construed as medical/diagnostic advice/endorsement/treatment or prescription. Use of this site is subject to our terms of use, privacy policy, advertisement policy. © 2024 Minerva Medical Treatment Pvt Ltd

Our comments section is governed by our Comments Policy . By posting comments at Medical Dialogues you automatically agree with our Comments Policy , Terms And Conditions and Privacy Policy .

Similar News